10.07.2015 Views

pdf (2140k) - Adcon Engineering Co

pdf (2140k) - Adcon Engineering Co

pdf (2140k) - Adcon Engineering Co

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

RRMINI-SCREEN ® SystemsMetal Box <strong>Co</strong>ntrollersMINI-SCREEN ® Metal Box <strong>Co</strong>ntrollerswith Fixed BlankingOptical Safety Systems• Choose from four models:- MSCD-2 with trip output for 115/230V ac operation, 2 N.O. FSDs- MSCD-2T3 with trip output for 115/230V ac operation, 2 N.O. & 1 N.C. Aux.- MSCT-2 with trip output for 24V dc operation, 2 N.O. FSDs- MSCT-2T3 with trip output for 24V dc operation, 2 N.O. & 1 N.C. Aux.• Fixed-beam blanking allows continued presence of an object in the defined area: easy push-buttonteach-mode programming of blanked beams• Selectable one- and two-beam floating blanking allows objects (usually workpiece material) tomove through the defined area at any point without tripping the final switching devices• Selectable auto power-up mode for applications where a key reset is difficult to perform• Welded steel box enclosure with tough black polyester powder paint finish; rated NEMA 13, IEC IP64MINI-SCREEN Metal Box <strong>Co</strong>ntroller with Fixed Blanking SpecificationsSystem Power RequirementsFuse RatingResponse TimeMSCD-2 & MSCD-2T3: 115/230V ac ±15% (50/60 Hz), 55 VAMSCT-2: 24V dc ±15%, 10% maximum ripple, 1.5 amps max.<strong>Co</strong>ntrol Box MSCD-2& MSCD-2T3: 115V ac: 1 amp, 250V; 230V ac: 1 /2 amp, 250V<strong>Co</strong>ntrol Box MSCT-2: 2 amp, 250V (all fuses 3 AG or 5x20 mm slow blow)Standard and Long-Range Sensors:Less than 48 ms using emitter/receiver with 114 mm (4.5") to 406 mm (16") defined areaLess than 60 ms using emitter/receiver with 508 mm (20") to 813 mm (32") defined areaLess than 72 ms using emitter/receiver with 914 mm (36") to 1219 mm (48") defined areaHeavy Duty Sensors:Less than 48 ms using emitter/receiver with 610 mm (24") to 813 mm (32") defined areaLess than 60 ms using emitter/receiver with 1016 mm (40") to 1626 mm (64") defined areaLess than 72 ms using emitter/receiver with 1829 mm (72") defined areaStatus Indicators(on control box and receiver)Diagnostic Indicators<strong>Co</strong>ntrols and AdjustmentsAuxiliary Monitor RelayOutput <strong>Co</strong>nfiguration:(FSD1, FSD2, and SSD)Enclosure<strong>Co</strong>nnectionsOperating <strong>Co</strong>nditionsRed = BLOCKED Flashing red = LOCKOUTGreen = CLEAR Flashing green = BLANKING ONYellow = RESET Double-flashing yellow = Waiting for Power-up Key ResetSingle-flashing yellow = ALIGNMENT. Flash rate increases with the number of sensing beams“made”, solid yellow when aligned and defined area is clear.Two-digit numeric display indicates cause of lockout conditionDisplay is visible through a window in the control box coverKeyed Reset of system lockout conditionsFloating Blanking selection switches and Fixed Blanking programming switchesAuto Power Up on-off switchesReed relay; 125V ac or dc max., 500 mA max. (10 VA maximum, resistive load)Forced-guided contact relay (resistive load).MSCD-..2: FSD1 & 2, SSD = 250V ac max., 4 amp max.MSCD-..3: FSD1 & 2, CNC = 250V ac max., 6 amp max.; SSD = 250V ac max., 4 amp max.Mechanical life: 10,000,000 operations (minimum).Electrical life: 100,000 operations (typical @ 1.0 kVA switching power).Arc suppression is recommended when switching inductive loads. See Warning on page 336.Size: see dimensions on next page.Material: welded steel box with black polyester powder paint finish.Environmental rating: NEMA 13, IEC IP64See page 337 for general hookup information.Temperature: 0° to +50°C (+32° to +122°F)Relative humidity: 95% maximum (non-condensing)FMEA Tested Per requirements IEC 61496-1 (type 4)Application NotesCertificationsUse of fixed blanking requires sensors with 16 or more light beams. Up to 12 beams or 30% of thetotal number of beams in the array may be blanked, whichever is less. Call factory for applicationsassistance if a greater number of blanked beams is required.PresenceSensingDevice116 Banner <strong>Engineering</strong> <strong>Co</strong>rp. • Minneapolis, MN U.S.A. • bannerengineering.com • Tel: 763.544.3164

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!