11.07.2015 Views

MP Research Catalog - Biopac

MP Research Catalog - Biopac

MP Research Catalog - Biopac

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

inhale to total lung capacity and then exhale forcefullyto residual volume. Integrate FEF to obtain forcedexpiratory volume (FEV). AcqKnowledge generates thespirometry curve via an X/Y plot of expired volume versusexpired flow. The FEF values can be measured directly onthe spirometry curve at the standard 25%, 50% and 75%volume points. To evaluate FEV, use AcqKnowledge topresent the spirometry curve data as a function of time. Todetermine FEV 0.5 and FEV 1.0 , place time cursors 1/2 secondand one second after the start of expiration, respectively.Volume/Flow Loop RelationshipsEasily compare normal tidal breathing loops to maximumbreathing loops by using the X/Y mode to plot flowversus volume.This graphicalrepresentationclearly indicatesthe subject’sreserve capacityin relation tonormal breathing.AcqKnowledgecan also be usedto automaticallydetermine thebreath-by-breathvolume/flow looparea as a function of time.Automatic Data ReductionPowerful automatic data reduction tools reduce large datafiles into manageable sizes. The data reduction tools canextract a variety of concise measurements from very longdata recordings. For example, it’s possible to extract themean tidal volume from consecutive 30-second periods.Record continuously for short- and long-term studies(24+ hours), or pre-program to record for specific timeperiods and dosing events. Automatically triggerpre-programmed trials to record the data around dosingperiods, 24 hours a day, seven days a week.Animal studies Q35The <strong>MP</strong> System will interfacewith a variety of pulmonaryfunction chambers to providedetailed on-line analysis ofpulmonary function data. Usethe TSD160 Series pressuretransducers to record plethysmogramchamber pressure. Alarge selection of very lowflow pneumotachs (TSD137Series) covers a wide range ofair flow rates. The softwarewill record the primarypressure and flow signalswhile on-line calculationchannels integrate the flowsignal and calculate resistance,compliance, respiration rate,and peak inspiratory andexpiratory flow.• On-line and off-lineanalysis: respirationrate, peak flow,minimum flow,volume, compliance,and resistance• Interface with existingplethysmogramchambers and airflow transducers• Signal markers torecord dosing andother events• Simple two pointcalibration procedure(mmHg, ml/min,etc.)• In-vitro and in-vivoapplicationsTypical Applications & Corresponding PartsHigh Flow Medium Flow Low Flow Very Low Flow(exercising human) (resting human) (child, pig, dog) (small animals)AFT2 MouthpieceXAFT3 Noseclip X XAFT6 Calibration Syringe X X XAFT7 Tubing X (2)AFT9 MouthpieceXAFT21 T ValveXAFT24 Head SupportX (optional)AC137 In-line TransformerXDA100C Amplifier X (2) X X XTSD107B Pneumotach (high) X (2)TSD117 Pneumotach (med.)XTSD127 Pneumotach (low)XTSD137 Pneumotach (very low)TSD137A Small mouse (30 gr)TSD137B Mouse (50 gr)TSD137C Rat/guinea pig (170 gr)TSD137D Cat/rabbit (750 gr)TSD137E Small dog (5.5 kg)HardwareOptions:39DA100C 54General-purposeTransducer AmplifierTSD107B 70Pneumotach Air FlowTransducer (High Flow)TSD117 73Pneumotach Air FlowTransducer (MediumFlow)TSD127 76Pneumotach Air FlowTransducer (Low Flow)TSD137Series 77Pneumotach Air FlowTransducers (Very LowFlow)TSD160Series 80High SensitivityDifferential PressureTransducersO2100C 62O 2 Measurement ModuleCO2100C 62CO 2 MeasurementModuleRSP100C 59Respiration PneumogramAmplifierTSD201 81Respiration TransducersAFT15A/B 90Mixing ChambersAFT21/22 91Non-rebreathing T ValvesAFT Series 89Air Flow & Gas AnalysisTransducer AccessoriesSKT100C 59Temperature AmplifierTSD202Series 82Temperature TransducersPart Options: AFT25 = AFT21 + AFT9 + AFT3 + AFT24AFT2 + AFT3 = AFT10 + AFT11B

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!