11.07.2015 Views

MP Research Catalog - Biopac

MP Research Catalog - Biopac

MP Research Catalog - Biopac

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

72TransducersTSD115Variable Assessment TransducerThe TSD115 incorporates a slide control with graduated scale that allows users togauge their subjective response to a variety of stimuli. Multiple TSD115transducers can be used simultaneously, allowing several people to answer the samequestion or otherwise respond to stimuli. The transducer is lightweight and fitseasily into the subject’s hand or lap. The TSD115 comes equipped with a 7.6-metercable and is designed for direct connection to the HLT100C module.• TSD115NEWTSD116Switches and MarkersTSD116CThe TSD116 series is used for externally triggering data acquisition, remote eventmarking, or psychophysiological response tests. The switches connect to theUIM100C digital I/O ports and can be monitored as input channels. The TSD116series incorporate momentary ON operation (switch is ON only when pressed). TheTSD116A is a single channelhand switch, the TSD116B is asingle channel foot switch and thenew TSD116C is a compact eightchannel digital marker box. TheTSD115 SPECIFICATIONSScale Output Range: 0-5 VScale Resolution: Infinitely adjustableSlide Control Length: 10 cmTSD116ATSD116BDimensions:TSD116C allows the user to independentlymark events, or provide Weight:230 gramsx 19cm (wide)responses, on up to eight channelsCable Length: 7.6 metersInterface: HLT100C—see page 53simultaneously. Because digital channels can be interleaved with analog channels, when usingAcqKnowledge, it’s easy to assign separate digital channels as event markers for individual analog TSD116 SPECIFICATIONSinput channels.• TSD116A• TSD116B• TSD116CNoninvasiveBlood PressureCuff TransducerThe TSD120 can measure systolicand diastolic blood pressure bythe oscillometric or auscultatory (Korotkoff sounds) technique. The TSD120 includes anadjustable cuff (standard adult cuff: RX120D), pump bulb, pressure gauge and pressure transducer.The pressure transducer is attached to the cuff and connects to the DA100C general-purposetransducer amplifier. To visually identify Korotkoff sounds during cuff deflation, use the TSD108physiological sounds microphone. For indication of relative blood pressure changes withoutcycling the cuff pressure, inflate the cuff to a pressure between systolic and diastolic.For absolute and continuous measurement of noninvasive blood pressure, use the NIBP100A;see page 68.• TSD120TSD120NEWSwitch Type:Dimensions:4cm (high) x 11cm (deep)Pushbutton: (ON) – OFFTSD116A: 19mm (dia),63mm (long)TSD116B: 69mm (wide),90mm (long), 26mm(high)TSD116C: 19cm (wide),11cm (deep), 4cm (high)Cable Length: TSD116A and TSD116B:1.8 meters, TSD116C: 3-metersConnector Type: TSD116A and TSD116B:2mm pin plugsTSD116C: Stripped andtinned wiresMRI Compatible: Yes (no ferrous parts) -TSD116A hand switchonlyInterface: UIM100C—see page 52TEL100C Compatibility:SS10 (Hand Switch)—seepage 67TSD120 SPECIFICATIONSCuff Circumference range:25.4cm to 40.6cm(RX120D cuff)Cuff Dimensions: 14.5cm (wide) x 54cm(long)Pressure Range: 20mmHg to 300mmHgManometer Accuracy: ±3mmHgOutput:5 µV/mmHg (normalizedto 1V excitation)Weight:350 gramsCable Length:3-metersInterface: DA100C—see page 54

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!