11.07.2015 Views

MP Research Catalog - Biopac

MP Research Catalog - Biopac

MP Research Catalog - Biopac

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

65STMISOD & STMISOESPECIFICATIONSStimulus Pulse Width:Stimulus Sine WaveRange:50µsec to 2msec(voltage only)100Hz to 5kHz (voltageonly)Step Up Voltage Ratio: STMISOD (1:5)STMISOE (1:10)Maximum OutputVoltage:Isolation Capacitance:Isolation Voltage:Cable Length:Weight:Dimensions:Interface:STMISOD 100V (p-p)into 5k Ω loadSTMISOE 200V (p-p)into 5k Ω load120pf1500 VDC(from amplifier ground)1.8 meters140 grams6.5cm (wide) x 5cm(deep) x 4.8cm (high)STM100C—see to leftStimulus Isolation Adapters (Voltage Only)The STMISOD and STMISOE can stimulate with pulse, sinusoidal or arbitrary waveformsand are suitable for nerve conduction, muscle twitch, somatosensory stimulation, or otherresponse studies requiring a voltage stimulus.The STMISOD and STMISOE plug into the STM100C to provide an isolated voltagestimulus. These stimulus isolation adapters incorporate a linear voltage multiplier toamplify the voltage signal from the STM100C. Voltage stimulation can be unipolar orbipolar, with a maximum voltage output of 100 volts for the STMISOD and 200 volts forthe STMISOE.• STMISOD (100V maximum)• STMISOE (200V maximum)See pages 83-85 for a wide range of electrode options.Additional STM Series Interface Cables:CBL200 and CBL204—see page 86.CBL102, CBL105 and CBL106 — see page 88.Auditory Stimulus AccessoriesHeadphonesThese monaural headphones can be used with the STM100C stimulator module to deliver a tone signal while recording data for startle responseor other stimulus-response studies. The headphones can also be used to listen to raw signals (such as EMG), piped through the STM100C from anamplifier output. The OUT100 is a wide response, high efficiency headphone, weighing 85 grams and is equipped with a 1.8 meter cordterminated in a 6.3mm (1/4") phone plug.• OUT100Tubephone SetUse the OUT101 tubephone with a STM100C stimulator module to deliver clicks and tonesin auditory evoked response applications (i.e. ABR). The Tubephone design consists of amonaural acoustic transducer attached to a short, flexible, plastic tube, which fits into thesubject’s ear with the aid of a foam tip. Use of the Tubephone reduces ambient noise and boneconduction problems, which can interfere with auditory response recordings. Furthermore,because the Tubephone provides a 1 msec acoustic signal delay (due to plastic tube), it automaticallyseparates true response from electromagnetic artifact resulting from speaker activation. TheOUT101 measures 3.8cm (wide) x 5cm (high) x 1cm (thick), includes a clip for attachmentto fabric or fixtures and comes equipped with a 1.8m cable terminated in a 6.3mm (1/4")phone plug. The OUT101 Tubephone Set includes one Tubephone, plastic tube and 50 foamear inserts. The OUT101 response compares to TDH-39, 49 or 50 audiometric headphones.• OUT101 (Tubephone Set)• OUT101T (Replacement Plastic Tubes: pkg. of 4)• OUT101E (Replacement Foam Ear Inserts: pkg. of 50)Piezo Audio TransducerNEWThe OUT102 piezo transducer is typically connected directly to the STM100C stimulator module. When the stimulator module output rises above1.5 volts, the piezo indicator will emit a constant audible signal (3.0 kHz @ 80dB). Accordingly, the device is very useful for providing an audiblestimulus, or alarm, when a physiological signal passes a certain threshold. As such, the OUT102 makes an excellent audible BPM indicator for ECG,blood pressure or respiration signals. The device can also be used to indicate when temperature or another slowly moving variable (e.g. electrodermalresponse) passes a certain threshold. The threshold for the OUT102 is determined by adjusting the amplitude control on the STM100C module.The specific Biopotential or Transducer amplifier signal monitored can be recorded while simultaneously directed through the STM100C module.The OUT102 also connects directly to the UIM100C digital I/O ports for operation with Control Channel outputs. The OUT102 measures 2.5cm(dia) x 1cm (high) and comes equipped with a 1.8m cable terminated in a 3.5mm phone plug. An adapter is included for connecting the OUT102to the UIM100C digital I/O ports.• OUT102OUT SeriesOUT100OUT102OUT101

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!