86Cables & AccessoriesDisks, Gel, PadsElectrode AccessoriesElectrode Site Preparation PadTo remove non-conductive skin cells and sensitize skin for optimal contact during recording, this 2.5cm x 5cmabrasive pad can be rubbed lightly across the skin before applying an electrode. Each ELPAD package contains10 abrasive pads.• ELPAD (Pkg. 10)Electrode GelGEL100 non-irritating gel is used as a conductant with the EL250 series reusable electrodes.Each tube contains 8 ounces of gel.• GEL100Adhesive CollarsThese double-sided adhesive collars are used to hold the EL250 series reusable electrodes firmly on the skin surface. Use the ADD204 (19mm OD, 4mmID) with the EL254, EL254S and EL254RT electrodes; use the ADD208 (22mm OD, 8mm ID) with the EL258, EL258S, EL258H and EL258RT electrodes.• ADD204 (Pkg. 100) • ADD208 (Pkg. 100)Tape SeriesAdhesive tape for attaching transducers or electrodes to the skin surface. Use TAPE1 (single sided tape) for securing Active Electrodes or otherdevices and use TAPE2 (double-sided tape) for attaching Goniometers to the skin surface.• TAPE1 (single-sided)Tape SeriesNEWGEL101 non-irritating, isotonic, gel is primarily used as a conductant for the TSD203 electrodermalresponse transducers (page 82).• GEL101 (4 oz.)• TAPE2 (double-sided)Lead Connector Conversion CablesConversion CablesCBL200This extensionCBL204CBL203(10cm) is requiredwhen convertingCBL200an old-style 2mmpin electrode ortransducer lead to aTouchproof socketCBL202CBL201(1.5mm ID) forconnection to anyof the 100C-seriesBiopotential orTransducer amplifier modules. Use one CBL200 per Touchproof socket.To connect a Touchproof electrode or transducer to an older 100B-seriesmodule with 2mm input sockets, use the CBL201.• CBL200CBL201Required when converting a Touchproof (1.5mm ID) socket electrodeor transducer lead to an old-style 2mm pin, for connection to any of the100B-series Biopotential or Transducer amplifier modules. Also used toconnect a ground electrode lead (e.g. LEAD110A) to the UIM100Cmodule (required when using the TSD150 active electrodes). OneCBL201 (10cm long) is required for each Touchproof socket.• CBL201CBL202This is a multi-purpose adapter to connect a phone cable to the digitalI/O lines on the UIM100C or to the input of the DA100C. Also connectsthe STM100C to nerve conduction chambers (CBL105 required). TheCBL202 is 10cm long and consists of a 6.3mm (1/4") phone socket leadingto a pair of 2mm plugs.• CBL202CBL203The CBL203 is primarily designed to connect YSI ® 400 series biomedicaltemperature probes to the SKT100C temperature amplifier, but it canalso be used to connect certain 6.3mm (1/4") mono phone plugterminated cables or transducers to the 100C-series Transducer orBiopotential amplifiers. The CBL203 is 10cm long and consists of a6.3mm (1/4") phone socket leading to a pair of Touchproof sockets.• CBL203CBL204This Touchproof “Y” electrode lead adapter (25cm long) is requiredwhen multiple electrode sites are to be connected to a single amplifierinput or stimulator output. The CBL204 plugs into any 100C-seriesBiopotential amplifier input or STMISO series output and provides twoplugs to connect to electrode leads terminating in Touchproof sockets.Multiple CBL204s can be plugged together to reference 3 or moreelectrode leads to the same input or output.• CBL204

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!