57EMG100C SPECIFICATIONSGain: 500, 1000, 2000, 5000Output Range: ±10V (analog)Low Pass Filter: 500Hz, 5000HzHigh Pass Filter: 1.0Hz, 10Hz, 100HzNotch Filter: 50dB rejection @ 50/60HzNoise Voltage: 0.2µV rms - (10-500Hz)Z (input):2MΩ (Differential)1000MΩ (Common mode)CMRR:110dB min (50/60Hz)CMIV:±10V (referenced toamplifier ground)±1500 VDC (referenced tomains ground)Input Voltage Range: Gain Vin (mV)500 ±201000 ±102000 ±55000 ±2EOG100C SPECIFICATIONSGain: 500, 1000, 2000, 5000Output Selection: Normal, Derivative outputOutput Range: ±10V (analog)Low Pass Filter: 35Hz, 100HzHigh Pass Filter: DC, 0.05HzNotch Filter: 50dB rejection @ 50/60HzNoise Voltage: 0.1µV rms - (0.05-35Hz)Z (input):2MΩ (Differential)1000MΩ (Common mode)CMRR:110dB min (50/60Hz)CMIV:±10V (referenced toamplifier ground)±1500 VDC (referenced tomains ground)Input Voltage Range: Gain Vin (mV)500 ±201000 ±102000 ±55000 ±2ERS100C SPECIFICATIONSGain: 5000, 10000, 20000, 50000Output Range: ±10V (analog)Low Pass Filter: 3kHz, 10kHzHigh Pass Filter: 1.0Hz, 20Hz, 100HzNotch Filter: 50dB rejection @ 50/60HzNoise Voltage: 0.5µV rms - (100-3000Hz)Z (input):2MΩ (Differential)1000MΩ (Common mode)CMRR:110dB min (50/60Hz)CMIV:±10V (referenced toamplifier ground)±1500 VDC (referenced tomains ground)Input Voltage Range: Gain Vin (mV)5000 ±210000 ±120000 ±0.550000 ±0.2ALL BIOPOTENTIALA<strong>MP</strong>LIFIER SPECIFICATIONSSignal Source:Dimensions:Weight:Electrodes (three electrodeleads required)4cm (wide) x 11cm (deep)x 19cm (high)350 gramsElectromyogram AmplifierThe EMG100C amplifies general and skeletal muscle electrical activity. The amplifierfunctions directly with AcqKnowledge to perform real-time EMG integration and, as itincorporates fast response and settling time characteristics, can also be used to monitorsingle-fiber EMG, motor unit and peripheral nerve action potentials.• EMG100CElectrooculogram AmplifierThe EOG100C amplifies the corneal-retinal potential. The amplifier monitors the DC potentialon the skin surrounding the eyes, which is proportional to the degree of eye movement in anydirection. The amplifier output can be switched between normal EOG output and Derivativeof EOG. In Derivative mode, the amplifier outputs the measured velocity of eye movement,which is useful for saccade and nystagmus investigations. The amplifier permits DC coupling toelectrodes for X/Y graphing of eye movement without discernible decay.• EOG100CEvoked Response AmplifierThe ERS100C is an extremely low noise differential amplifier that accurately amplifies verysmall potentials, such as those associated with stimulus/response, signal-averaged recordings.Selectable gain and bandwidth options make the module useful for a variety of evoked responsetesting modes. The ERS100C is intended for use in applications such as auditory brainstemresponse, startle response, somatosensory evoked response or nerve conduction velocity recording.• ERS100CBiopotential 100C Interface CablesCBL200—see page 86CBL204—see page 86 JU<strong>MP</strong>100C—see page 87The Biopotential amplifiers connect to unshielded or shielded electrodeleads terminating with Safelead ® / Touchproof (1.5mm) sockets. Forbest performance, use two shielded electrode leads and one unshieldedelectrode lead per amplifier. See the extensive selection of electrodeleads on page 83. For additional electrode lead distance, see theModule Extension Cables on page 87.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!