76TransducersTSD127All connections can be performed with AFT11 series couplers (see page 90).• TSD127Pneumotach Air Flow Transducer (Low Flow)NEWThe TSD127 can perform a variety of pulmonary measurements relating to air flow, lungvolume and expired gas analysis. The transducer includes a detachable flow head (RX127) foreasy cleaning and sterilization. The TSD127 is intended for animal use and consists of a lowflow, pneumotach air flow head (RX127) coupled to a precision, highly sensitive, differentialpressure transducer (TSD160A). The TSD127 will connect directly to a breathing circuit orplethysmogram chamber.• For air flow and lung volume TSD127 SPECIFICATIONSmeasurements, connect a short air flow Range:± 90 Liters/minNominal Output: 500 µV/[liters/sec] (normalizedto 1V excitation)cannula to theTSD127.• For measurements of expired gases, Dead Space: 11ccMRI Compatible: Yes (no metal parts) – airuse the TSD127 with the AFT22flow headWeight:11 grams – air flow headnon-rebreathingvalve.Dimensions: 5.7cm (long) – air flowheadPorts:15mm OD / 11mm IDTubing Length: 1.8 meters (to DA100C)Interface: DA100C—see page 54Replacement Air Flow Head for the TSD127The RX127 is the replacement low air flow head for the TSD127 pneumotach transducer. Multiple RX127heads help eliminate equipment downtime during cleaning procedures. (11mm ID/15mm OD)RX127NEWRX127TSD130 SeriesGoniometersThe TSD130 series goniometers measure limb angular movement. Goniometersattach to the body using TAPE2 medical adhesive tape. The units have atelescopic endblock that compensates for changes in distance between thetwo mounting points as the limb moves. The gauge mechanism allows for accuratemeasurement of polycentric joints. A DA100C is required for each output channel;accordingly, the twin-axis goniometers require two DA100C amplifiers to measureboth axes simultaneously.• The TSD130A and TSD130B are dual output devices used for simultaneous measurements around two orthogonal rotational axes (e.g., wristflexion/extension and radial/ulnar deviations).• The TSD130C and TSD130D are single outputdevices used to measure axial rotation about a singleplane (e.g., forearm pronation/supination).• The TSD130E (single-axis goniometer) is used tomeasure finger joint movement.• TSD130A• TSD130B• TSD130C• TSD130D• TSD130ETSD130 SPECIFICATIONSType Channels Max Length Min Length Range WeightTSD130A Goniometer 2 110mm 75mm ± 180° 17gTSD130B Goniometer 2 180mm 130mm ± 180° 19gTSD130C Torsiometer 1 110mm 75mm ± 90° 17gTSD130D Torsiometer 1 180mm 130mm ± 90° 19gTSD130E Goniometer 1 35mm 30mm ± 180° 8gNominal Output: 5 µV/degree (normalized to 1V excitation)Cable Length: 3-metersInterface: DA100C—see page 54TEL100CCompatibility: SS20 thru SS24—see page 67

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!