11.07.2015 Views

MP Research Catalog - Biopac

MP Research Catalog - Biopac

MP Research Catalog - Biopac

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

68Noninvasive Arterial BPNIBP100ANoninvasive Direct Arterial BloodPressure Monitor NEWThe noninvasive NIBP100A provides continual blood pressure measurement withaccuracy comparable to an indwelling radial artery catheter. The NIBP100A is anaccurate, continual, and noninvasive solution to blood pressure monitoring.Using a patented method of measuring radial artery waveforms, the NIBP100A systemcalculates accurate systolic, diastolic, and mean pressures. The data is processed by aproprietary algorithm based on a set of coefficients derived from clinical data.No complicated setup or calibration requirements!The NIBP100A is easy to use. The pressure sensor in the NIBP100A applies variablepressure directly above the radial artery and the initial measurement and waveform aredisplayed within 15 heartbeats. The display is continually updated every 10-15 heartbeats.Subjects experience minimal sensation while wearing the wrist sensor. The wrist sensorfits adults or children (22-11 cm), can be worn on either wrist, and is completelylatex-free. The NIBP100A also provides improved ability to obtain measurementsfrom subjects undertaking light exercise or psych analysis conditions.For a low-cost alternative to measure non-continuous,indirect blood pressure, see the TSD120 on page 72.For invasive blood pressure, see TSD104A on page 69.NIBP100A SPECIFICATIONSMonitor:Displays:Electrical:Performance Range:Trend:Clock speed:Interface:Case: AluminumSize: 5.0 (h) x 4.5 (w) x 8.5 (l) -- inchesWeight: 4.5 lbs with power cord and wrist moduleLCD: Cold Cathode Fluorescent Backlight (CCF)LED: Three (3) high-intensity displaysRatings: 100-240 VAC, 50/60 Hz, 0.25 - 0.5A max.Current Leakage: UL544Min/Max AccuracySystolic: 40mmHg-240mmHg+ 5mmHg/SD 8mmHgMean: 30mmHg-200mmHg+ 5mmHg/SD 8mmHgDiastolic: 20mmHg-180mmHg+ 5mmHg/SD 8mmHgPulse: 40 bpm - 200 bpm+ 5 bpm or 10%Updated tabular and graphical trends following each reading, up toapproximately 900 readings.33MHz/min; provides reliable, high-speed digital signal processing.DA100C with TCI105.The NIBP100A is classified to U.S. and Canadian safety standards with respect to electric shock,fire, and mechanical hazards in accordance with UL2601-1 and IEC 60601-2-30.The sensor requires replacement every six months--use BIOPAC Part No. RXNIBPA. Thesensor also has a 24-month shelf life and should be used within that time frame.TSD105A SPECIFICATIONSRated Output: 1mV/V (normalized to 1Vexcitation)Ranges: 50, 100, 200, 500, 1000gramsNoise (rms): (Range/50)mg @ 10 voltsexcitation, 1Hz bandwidthNonlinearity:

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!