62Gas AnalysisC02100C & 02100CCO2 Measurement ModuleAFT20 gas sampling interface kit)with the AFT15A and AFT15Bmixing chambers, the AFT21 andAFT22 non-rebreathing T valves orthe AFT25 mask with integralnon-rebreathing T valve.The CO2100C module is equippedwith a variable speed pump to adjustthe flow over a wide range ofsampling conditions. The moduleemploys a single beam, infrared, single wavelength, measurement technique. Sampling lineconnections for input and output flow are readily accessible on the front panel of the module.Includes In-line Transformer (AC100A); specify USA or EURO power cord.• CO2100CBIOPAC offers a broad range of airflow transducers and gas analysisaccessories — see pages 89-91.O2 Measurement ModuleThe O2100C module records quickly varying oxygen concentration levels. This fast responseanalyzer is ideal for monitoring time-averaged O 2 levels using mixing chambers or real-time O 2levels for breath-by-breath measurements. The O2100C module interfaces (via the AFT20 gassampling interface kit) with the AFT15A and AFT15B mixing chambers, the AFT21 andAFT22 non-rebreathing T valves or the AFT25 mask with integral non-rebreathing T valve.The O2100C module is equipped with a variable speed pump to adjust the flow over a widerange of sampling conditions. The module employs an analysis technique based on theparametric oxygen measurement principle. Sampling line connections for input and output floware readily accessible on the front panel of the module.Includes In-line Transformer (AC100A); specify USA or EURO power cord.• O2100CThe CO2100C module records quickly varying carbon dioxide concentration levels. Thisfast response analyzer is ideal for monitoring time-averaged CO 2 levels using mixingchambers or real-time CO 2 levels for breath-by-breath measurements. TheCO2100C module interfaces (via theCO2100C SPECIFICATIONSCO 2 Range: 0-10% CO 2Gain:1, 2, 5, 10 (%CO 2 /Volt)Output Range: 0-10 voltsRepeatability: 0.03% CO 2Resolution: 0.1% CO 2Linearity: 0.1% CO 2Zero Stability: 0.1% CO 2 /24 hoursResponse Time: 90msec (T10-T90) @ 200ml/min100msec (T10-T90) @ 100ml/min (factory preset)130msec (T10-T90) @ 50ml/minFlow Range: 50-200 ml/minTemp Range: 10-45°CZero Drift:0.01% CO 2 /°CSpan Drift:0.02% CO 2 /°CWarm Up Time: 5 minutes @ 25°CSampling Port: Male LuerWeight:740 gramsDimensions: 7cm (wide) x 11cm (deep)x 19cm (high)Power Source: 12VDC @ 1 amp (usesAC100A transformer)The module measures the partial pressure ofCO 2 so the module output is a function of thepressure in the sample cell. Gas sampled mustbe free of any liquid or condensable vapors.Gas should be filtered to 5 microns or better.The module utilizes Servomex, Inc. technologyfor CO 2 concentration signal processing.02100C SPECIFICATIONSO 2 Range: 0-100% O 2Gain:10, 20, 50, 100 (%O 2 /Volt)Output Range: 0-10 voltsRepeatability: ±0.1% O 2Resolution: 0.1% O 2Linearity: ±0.2% O 2Zero Stability: ±0.01% O 2/hrResponse Time: 160msec (T10-T90)@ 200 ml/min500msec (T10-T90)@ 100 ml/min(factory preset)1000msec (T10-T90)@ 50 ml/minFlow Range: 50-200 ml/minTemp Range: 5-50°CZero Drift:±0.05% O 2 /°CSpan Drift±0.25% O 2 /°CSampling Port: Male LuerWeight:990 gramsDimensions: 7cm (wide) x 11cm (deep)x 19cm (high)Power Source: 12VDC @ 1 amp (usesAC100A transformer)The module measures the partial pressure ofO 2 so the module output is proportional to thepressure in the sample cell. Gas sampled mustbe free of any liquid or condensable vapors.Gas should be filtered to 5 microns or better.The module utilizes Servomex, Inc. technologyfor O 2 concentration signal processing.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!