11.07.2015 Views

MP Research Catalog - Biopac

MP Research Catalog - Biopac

MP Research Catalog - Biopac

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

81TSD200 SPECIFICATIONSEmitter/DetectorWavelength: 860nm± 60nmOptical Lowpass Filter: 800nmWeight:4.5 gramsDimensions: 16mm (long) x 17mm(wide) x 8mm (high)Attachment: Velcro ® strapMRI Compatible: Yes (no ferrous parts)Sterilizable: Yes (see BIOPAC fordetails)Nominal Output: 20mV (p-p)Power:6VDC Excitation @ 5mACable Length: 3-meters (shielded)Interface: PPG100C—see page 58TEL100C compatibility: SS4—see page 67TSD201 SPECIFICATIONSTrue DC Response: YesCircumference Range: 15cm x 150cm (increasedwith a longer strap)Sensor Dimensions: 66mm (long), 40mm(wide), 15mm (thick)Sensor Weight: 18 gramsAttachment: Velcro ® strap (adjustablelength)MRI compatible: Yes (no ferrous parts)Sterilizable: Yes (contact BIOPAC fordetails)Variable ResistanceOutput:5-125 KΩCable Length: 3-meters (shielded)Interface: RSP100C—see page 59TEL100C compatibility: SS5B—see page 67Photo-Electric Pulse Plethysmogram TransducerThis transducer operates with the PPG100Camplifier to record the pulse pressure waveform.The TSD200 consists of a matched infraredemitter and photo diode, which transmitschanges in infrared reflectance resultingfrom varying blood flow. The ergonomichousing design improves contact with thesubject and helps reduce motion artifact.The TSD200 is primarily designed for fingerattachment, but can be taped to other bodylocations. The TSD200 comes with ashielded 3-meter cable.• TSD200TSD200Use BIOPAC transducers withother recording systems. Call forthe appropriate wiring instructionsto interface with existing amplifiers.Respiratory Effort TransducerTSD201The TSD201 connects to the RSP100C Respiration Amplifier to record respiratory effort. Thetransducer measures the changes in thoracic or abdominal circumference that occur as thesubject breathes. The design presents minimal resistance to movement and is extremely unobtrusive.Due to its novel construction, the TSD201 can measure arbitrarily slow to very fast respirationpatterns with no loss in signal amplitude, while maintaining excellent linearity and minimalhysteresis. The transducer comes with a shielded 3-meter cable and an adjustable Velcro ® strapto fit a wide range of subjects.• TSD201Are you being asked to include full pulmonary mechanics studies in your protocol?If so, BIOPAC has the complete solution, from mice to men. See the PulmonaryFunction Application on page 38 and discover the new range of Differential PressureTransducers and Air Flow & Gas Analysis products.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!