11.07.2015 Views

MP Research Catalog - Biopac

MP Research Catalog - Biopac

MP Research Catalog - Biopac

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

80TransducersActive ElectrodesThe TSD150 series active electrodes are designed for multiple-channel surface EMG measurements. The units incorporate a built-in high-gainamplifier with an integral 500 Hz lowpass filter. The unique design allows you to easily convert the surface contact electrodes to wire needleelectrodes for intricate sub-dermal procedures. The TSD150 series active electrodes connect directly to the <strong>MP</strong> System via the HLT100Chigh-level transducer module. The TSD150 series are very easy to use—locate theposition and hold in place with TAPE1 surgical tape. A single ground lead (CBL201 TSD150 Seriesand LEAD110A with EL503 electrode) to the UIM100C is required when using oneor more TSD150 series active electrodes.• TSD150A - Wide electrode placement (35mm apart)• TSD150B - Narrow electrode placement (20mm apart)TSD155CMulti-lead ECG CableNEWHigh Sensitivity DifferentialPressure Transducers NEWTSD160 SeriesThe TSD155C multi-lead ECG cable is used for performing a standard 12-lead ECG recordingusing only 3 ECG100C amplifiers. The TSD155C permits simultaneous recording of Leads I, II, III,aVR, aVL, aVF and one (movable) precordial lead [V1, V2, V3, V4, V5 or V6]. The TSD155C is3-meters long and incorporates a built-in Wilson Terminal. For full simultaneous 12-lead ECG, seethe WT100C Wilson Terminal on page 87.Interface: ECG100C—see page 56TEL100C compatibility: SS29—see page 67• TSD155Cvariety of small animalpneumotachs or plethysmographsto the <strong>MP</strong>System. The transducersare extremely sensitive andcome in three ranges tosuit a number of differentapplications. RX137 flow heads (page 77) connect to theTSD160A differential pressure transducer via standard 4mm IDtubing.• TSD160A (±2.5cm H 2 O)• TSD160B (±12.5cm H 2 O)• TSD160C (±25cm H 2 O)New software features make it even easier to provide a complete ECG analysis.See the Cardiology section on page 24 for a detailed explanation.The TSD160 series differential pressure transducers aredesigned for low range pressure monitoring. The transducersplug directly into the DA100C general-purpose differentialamplifier. The differential pressure ports are located onthe front of the transducers and are easily connected tobreathing circuits, pneumotachs or plethysmographboxes. These transducers are very useful for interfacing aTSD150 SPECIFICATIONSGain:350 (nominal)Fine Wire Attachments: Screw SpringsInput Impedance: 100MΩCMRR:95dB (nominal)Bandwidth:12Hz – 500HzElectrode Diameter: 11.4mmWeight:9.5 gramsDimensions:17.4mm (wide) x51mm (long) x 6.4mm(high)Cable Length:3-metersInterface: HLT100C—see page 53TSD160 SERIES SPECIFICATIONSTSD160A TSD160B TSD160COperational Pressure: ±2.5cm H 2 O ±12.5cm H 2 O ±25cm H 2 OOverpressure (max): ±250cm H 2O ±375cm H 2O ±375cm H 2OVoltage Output (normalizedto 1 volt excitation): 330 µV/cm H 2O 130 µV/cm H 2O 65 µV/cm H 2OWarm-up Drift:±50µVStability:±100µVCombined Linearityand Hysteresis Error: ±0.05%Dynamic Response: 100HzConnection Ports: Accepts 3mm to 4.5mm ID tubingDimensions:8.3cm (high) x 3.8cm (wide) x 3.2cm (deep)Weight:76 gramsOperating Temperature: 0 to +50 °C (compensated)Storage Temperature: -40 to +125 °CInterface: DA100C—see page 54

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!