DRIVE COMMAND SET WRITE (2AH - 10 BYTE)Table 45. Write Sense Key ReturnCONDITIONSENSE KEY (HEX)Invalid Logical Block Address ILLEGAL REQUEST (05)Target Reset, Media Change or Controller Detected Errorsince the Last Command from this InitiatorUNIT ATTENTION (06)Unable to Write or Controller Detected Error HARDWARE ERROR (04)Message Protocol or SCSI Data Transfer ErrorABORTED COMMAND (0B)Attempt to Write a Previously Written Block BLANK CHECK (08)NOTEChanges to the IB and CSIB in REQUEST SENSE data:On failed WRITE commands, the Information Bytes (bytes 3-6) willreport the highest sequential LBA written during that WRITEcommand, plus one. The next WRITE can be started at this LBA.When the Sense Key is BLANK CHECK, the information bytes will beset to the first non-blank block detected.The Command Specific Information Bytes (bytes 8-11) will equal thehighest sequential LBA written AND verified during that command,plus one. All data from the CSIB to the end of the current extent hasnot been verified. All data from the starting LBA up to, but notincluding, the CSIB has been verified.NOTEByte 9, Bit 6 invokes disable verify.PLASMON L M S - LD 6100/LF 6600/LF 6602 SCSI INTERFACE SPECIFICATIONPage 120