C h a p t e r 1 – G e t t i n g S t a r t e dTotal Supported Devices & LimitsListed below are the total numbers of devices by type that can be connected to a <strong>BaseStation</strong><strong>3200</strong>. The <strong>BaseStation</strong> <strong>3200</strong> can communicate with a maximum of 110 devices (device loads) onthe two-wire path within the layout and length limits outlined later in this section.Two-Wire Device Type Total Device LoadsField (Valve) biCoders 200 1 per biCoder5200R series biCoders 20 2 per biCoderbiSensors 25 1Master Valves/Pump Starts 4 1Flow Meters 4 3Pause Devices 4 1Up to 110 total device loads are supported, and only 200 zones may be configured in the <strong>3200</strong> or<strong>3200</strong>R controller.Unused ports or serial numbers on biCoders do not occupy a zone address and do not counttowards the 200 zone limit.Maximum Concurrent ValvesThe maximum number of concurrently operating valves is shown in the two tables below, andvaries based on the total load count and wire length to the farthest device:Maximum Wire Distances for <strong>3200</strong>R and 5200R series biCodersPage 25<strong>Baseline</strong> <strong>3200</strong>