11.07.2015 Views

BaseStation 3200 User Manual - Baseline Systems

BaseStation 3200 User Manual - Baseline Systems

BaseStation 3200 User Manual - Baseline Systems

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

C h a p t e r 5 – R e f e r e n c econditions then use the + or – keys to scroll between each of them. Each pausecondition can be cleared by pressing the CLR key, however, if the cause of the pausecondition has not be changed, the pause state will return. As seen in this example ofa water window pause, it cannot really be cleared with the CLR key. This will clearitself when the water window has expired, or when the water window programmingis changed. The following is a list of pause conditions:BL-Commander(handheld radio)BaseManager(central controlsoftware)All programs will be paused while running a zone usingthe remote handheld radio – all programs will resumewhen the zone is shut off.Use CLR to terminate the manual zone.Automatically cleared with zone is done.Normal operation will continue while the controller isaccessed by BaseManager.Use CLR to terminate the BaseManager connection.Automatically cleared with BaseManager logs off.Event Day An event day will stop all watering and keep programsfrom starting.Use CLR to terminate the event day.Automatically cleared when the event day ends.Flow Devices A high-flow shutdown or an over-budget shutdown willstop watering from using the specific flow device.Use CLR to reset a high flow shutdown condition.A CLR will not clear an over budget condition – changethe budget or wait until next month.Not automatically cleared – user must clear this.Flow Switch An open jumper or flow switch will stop all wateringand keep all programs from starting.A CLR will not reset this condition. Replace the jumperor reset the flow switch hardware.Not automatically cleared – user must clear this.LowTemperatureA temperature below 38 F. will pause all watering.A CLR will not reset this condition and you must waituntil the temperature rises.Automatically cleared with higher temperatures.Pause biCoder A pause bicoder will pause watering on specificprograms.A CLR will reset the pause condition before the delaytime has elapsed.Automatically cleared at end of delay time.Page 57<strong>Baseline</strong> <strong>3200</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!