Appendix B: Frequently Asked QuestionsCode Detail Code Item Description24 01 Condition Climate Sensor is not connected.DetectedAction 1. Check Climate Sensor connection.2. Replace Climate Sensor.3. Replace Printer Controller PCB.25: Paper Suction Fan Error25 01 ConditionDetectedAction26: Power Supply Fan Error26 01 ConditionDetectedAction26 02 ConditionDetectedAction27: Cooling Fan Error27 01 ConditionDetectedAction29: Wipe Valve Error29 20 ConditionDetectedAction29 21 ConditionDetectedActionPaper Suction Fan is faulty or not connected.1. Check for a clogged fan.2. Check Suction Fan connector connection.3. Replace Suction Fan.4. Replace Printer Controller PCB.Power Supply Fan is faulty or not connected1. Check for a clogged fan.2. Check Power Supply Fan connectorconnection.3. Replace Power Supply Fan.4. Replace Printer Controller PCB.Power Supply Fan is faulty or not connected1. Check for a clogged fan.2. Check Power Supply Fan connectorconnection.3. Replace Power Supply Fan.4. Replace Printer Controller PCB.Power Supply Fan is faulty or not connected1. Check for a clogged fan.2. Check Power Supply Fan connectorconnection.3. Replace Power Supply Fan.4. Replace Printer Controller PCB.Wipe Valve position error1. Check Wipe Valve Sensor connectorconnection.2. Check Valve Motor connector connection.3. Replace Wipe Valve Sensor.4. Replace Valve Motor.5. Replace Valve Unit.Wipe Valve position error1. Check Valve Motor connector connection.2. Replace Valve Motor.Page 202100-11672 - Rev D

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!