Technical details System pro M compact®

Technical details System pro M compact®

Technical details System pro M compact®

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>System</strong><strong>pro</strong> M compact ®<strong>Technical</strong> <strong>details</strong>Accessories for measurementinstrumentsMeasurementdevicesBalanced three-phase line without neutral (3 wires)10 V d.c.5 V d.c.1 V d.c.4÷20 mA d.c.20 mA d.c.10 mA d.c.400 V 230 V5 mA d.c.1 mA d.c.1 mA CC (segnaleanalogico)CThe output selection must be performed bymoving the <strong>pro</strong>gramming pushbuttons accordingto the specific needs.SELECTABLE OUTPUTS- + + -13 14 16 1721 23 24If a V output has been selected it is necessaryto connect terminals 13 and 14, while for mAoutputs the terminals 16 and 17 must beconnected. For supplying the device at 230 Vconnect the common terminal “C” and theterminal 23, while for a 400 V supply it isnecessary to connect the common terminal “C”and the terminal 21.L1L2L31 2 10 125 AVS1 S2P1 P2Pushbutton for signal switchLeftProportional to the cosϕ.RightProportional to the phase angle(output in grades, for insertionwith analogue reading instrument).Connect input voltage to terminals 10 and 12.Connect input current of L1 phase to terminals1 and 2.2CSC445014F090111ABB11/111