Technical details System pro M compact®

Technical details System pro M compact®

Technical details System pro M compact®

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>System</strong><strong>pro</strong> M compact ®<strong>Technical</strong> <strong>details</strong>Coordination tables:selectivityMCBsMCB S 700 - fuse gL/gG11Short circuit selectivity: In the case of a short circuit, selectivity exists up to the values indicated.short circuit discrimination in kAto main circuit breaker S 700 to fuse gL/gG (DIN VDE 0636; IEC 269/3)I nA 16 20 25 35 40 50 63 80 100 16 20 25 35 50 63 80 100 125 160S 200 2 15 15 15 15 15 15 15 15 15 1 1.2 4 15 15 15 15 15 15 15B, C, D 3 10 10 10 10 10 10 10 8 8 0.3 0.7 1.2 4.6 6 6 6 6 6 6Current values smaller 4 10 10 10 10 10 10 10 8 8 0.3 0.6 0.9 2.8 6 6 6 6 6 6than 6 A and 8 A,apply only to C and D 6 10 10 10 10 10 10 10 8 8 0.2 0.5 0.8 2 3.3 5.5 6 6 6 6characteristics 8 10 10 10 10 10 10 10 8 8 0.2 0.4 0.7 1.7 2.8 4.5 6 6 6 610 10 10 10 10 10 10 10 8 8 0.2 0.4 0.7 1.5 2.5 3.5 5 6 6 613 10 10 10 10 10 10 10 8 8 0.7 1.5 2.5 3.5 5 6 6 616 10 10 10 10 10 10 10 8 8 1.3 2 2.9 4.1 6 6 620 10 10 10 10 10 10 8 8 1.8 2.6 3.5 5 6 625 10 10 10 10 10 8 8 1.8 2.6 3.5 5 6 632 10 10 10 10 8 8 2.2 3 4 6 640 ** 10 10 10 8 8 2.5 4 6 6 650/63 10 10 8 8 3,5 5 6S 200 M 2 15 15 15 15 15 15 15 15 15 1 1.2 4 15 15 15 15 15 15 15B, C 3 15 15 15 15 15 15 15 10 10 0.3 0.7 1.2 4.6 6 6 6 6 6 6Current values smaller 4 15 15 15 15 15 15 15 10 10 0.3 0.6 0.9 2.8 6 6 6 6 6 6than 6 A and 8 A, applyonly to C characteristics 6 15 15 15 15 15 15 15 10 10 0.2 0.5 0.8 2 3.3 5.5 6 6 6 68 15 15 15 15 15 15 15 10 10 0.2 0.4 0.7 1.7 2.8 4.5 6 6 6 610 15 15 15 15 15 15 15 10 10 0.2 0.4 0.7 1.5 2.5 3.5 5 6 6 613 15 15 15 15 15 15 15 10 10 0.7 1.5 2.5 3.5 5 6 6 616 15 15 15 15 15 15 15 10 10 1.3 2 2.9 4.1 6 6 620 15 15 15 15 15 15 10 10 1.8 2.6 3.5 5 6 625 15 15 15 15 15 10 10 1.8 2.6 3.5 5 6 632 15 15 15 15 10 10 2.2 3 4 6 640 ** 15 15 15 10 10 2.5 4 6 650/63 15 15 10 10 3.5 5 6S 200 2 15 15 15 15 15 15 15 15 15 0.3 1.2 4 15 15 15 15 15 15 15K 3 10 10 10 10 10 10 10 10 10 0.3 0.7 1.2 4.6 6 6 6 6 6 6Selectivity values apply 4 10 10 10 10 10 10 10 10 10 0.3 0.6 0.9 2.8 6 6 6 6 6 6to Icu according to IEC947-26 10 10 10 10 10 10 10 10 10 0.7 1.7 3 5.9 6 6 6 68 10 10 10 10 10 10 10 10 10 1.3 2.2 3.6 6 6 6 610 10 10 10 10 10 10 10 10 10 1.7 2.5 4 6 6 616 10 10 10 10 10 10 10 10 10 2.2 3.1 4.6 6 620 10 10 10 10 10 10 10 10 3.1 4.6 6 625 10 10 10 15 10 10 10 2.6 3.5 6 632 10 10 10 10 10 10 3.5 6 640 ** 10 10 10 10 10 5.5 650/63 10 10 10 10 6S 200 2 15 15 15 15 15 15 15 15 15 0.5 2 15 15 15 15 15 15 15 15Z 3 10 10 10 10 10 10 10 10 10 0.3 0.7 1.2 6 6 6 6 6 6 6Selectivity values apply 4 10 10 10 10 10 10 10 10 10 0.3 0.6 1.3 7 6 6 6 6 6 6to Icu according to IEC947-26 10 10 10 10 10 10 10 10 10 0.2 0.5 0.9 2.7 6 6 6 6 6 68 10 10 10 10 10 10 10 10 10 0.2 0.5 0.6 1.7 3.8 6 6 6 6 610 10 10 10 10 10 10 10 10 10 0.4 0.6 1.3 2.4 4 6 6 6 616 10 10 10 10 10 10 10 10 10 0.5 1.1 1.7 3 4.5 6 6 620 10 10 10 10 10 10 10 10 0.9 1.5 2.3 3.5 5.2 6 625 10 10 10 15 10 10 10 1.4 2 3 4 6 632 10 10 10 10 10 10 1.4 2 3 4 6 640 ** 10 10 10 10 10 2 3 4 6 650/63 10 10 10 10 2.2 3.5 5.8 6** Limited or no selectivity at all possible in the overload range (thermal tripping)11/38 ABB

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!