12.07.2015 Views

FLH PDDM Chapter 9 - Eastern Federal Lands Highway Division

FLH PDDM Chapter 9 - Eastern Federal Lands Highway Division

FLH PDDM Chapter 9 - Eastern Federal Lands Highway Division

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

9.4.D. Earth Retaining Structures. (continued)List of owner agencies using the system, including contact names, addresses, and phone numbers. The listshall include documentation that the system has a successful "track record" of several installations. Theactual number of successful installations required will depend on the <strong>FLH</strong> reviewers' concerns, butnormally will be between 2 and 10 installations.Details of wall elements, analysis of structural elements, design calculations, factors of safety, estimatedlife, corrosion design procedure for soil reinforcing elements, procedure for field and laboratory evaluationincluding instrumentation, and special requirements, if any.Sample material and construction control specifications showing materials type, quality, certifications, fieldtesting, acceptance and rejection criteria, and placement procedures.A well documented field construction manual describing in detail, with illustrations where necessary, thestep by step construction sequence.Typical unit costs supported by data from several actual projects.A certification of the product and procedure by an independent Professional Engineer.Types of architectural facing treatments available or possible.Normally the <strong>Division</strong> Geotechnical Engineers will be responsible for coordinating the review. The principlereviewer shall determine if the system warrants further review. The reviewer shall insure all informationneeded from the above list has been provided.The principle reviewer shall determine if additional reviews by Geotechnical Engineers, Bridge Engineers, andother technical expert within <strong>FLH</strong>, the FHWA, or outside consultant firms are needed.Much of the information requested from the suppliers is needed to determine the acceptance of the designprocedure. However, some of the data is to permit the reviewers to develop additional information fordesigners and Project Managers:ConstructabilityVersatility/suitability for varying site conditionsSuitability for Architectural FacingLimitations on usage (Maximum Fill Heights, etc.)The principle reviewer shall send copies of the review package they determine to be acceptable to <strong>FLH</strong>O andthe other <strong>FLH</strong> divisions for concurrence. All retaining wall systems considered for use on <strong>FLH</strong> projects shallbe included in the Guidelines for Design of Retaining Wall Systems. A new retaining wall system shall notbe added to the list until all design guidelines, wall system limitations, and materials and constructionspecifications have been developed and approved for inclusion.9 - 88

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!