P92x/EN FT/H42Page 22/70[59N] filterNoTechnical GuideUser Guide<strong>MiCOM</strong> <strong>P921</strong>/<strong>P922</strong>/<strong>P923</strong><strong>P922</strong> an <strong>P923</strong> onlyDescription: Activates a software Band-pass filter (60 dB /decade attenuation) centered on the fundamental value (50 or60 Hz), in order to insure that residual over voltage function(59N) is immune to 10Hz & 200Hz frequency. In 3Vpp+Vr,3Vpn+Vr or 2Vpp+Vr connection mode configuration, Vrchannel is filtered. In 3Vpn connection mode, Va, Vb and Vc arefiltered.VaVbVectorial SumV0VcVrVrBandpass filter[59N]Connection mode[59N] filter acivatedP3999ENaRange: Yes/NoPlease refer to “Connection diagrams” section of this Technical Guide for thecomplete description of the connection schemes.2.3.2 "VT RATIO" SubmenuThis menu is common to the <strong>MiCOM</strong> <strong>P921</strong>, <strong>P922</strong> and <strong>P923</strong> relays. It makes itpossible to configure the VT ratios.To gain access to the “VT RATIO” submenu from the “CONFIGURATION” menu,press followed by or until the desired submenu header is displayed.CONFIGURATIONVT RATIOHeading of the “CONFIGURATION” submenu. To gain accessto the CONFIGURATION menu from the default display press followed by or until the menu is displayed.Heading of the “VT RATIO” submenuMAIN VT PRIMARY20.00 kVMAIN VT SEC’Y100 VE/Gnd VT PRIMARY20.00 kVE/Gnd VT SEC’Y100 VDescription: Primary of the voltage transformer(s) feeding therelayRange: 0.1-100kV, step =0.01kV (for the “57-130V”model)220-480V, step=10V (for the “220-480V” model)Description: Secondary of the voltage transformer(s) feedingthe relayRange: 57-130V, step=0,1V (for the “57-130V” model)Note: no VT secondary voltage for the “220-480V” modelDescription: Primary of the residual voltage transformer (ifconfigured)Range:0.1-100kV, step =0.01kV (for the “57-130V”model)220-480V, step=10V (for the “220-480V” model)Note: this message only seen if "3Vpn+Vr", "3Vpp+Vr" or"2Vpp+Vr" connection selectedDescription: Secondary of the residual voltage transformer (ifconfigured)Range: 57-130V, step=0.1V (for the “57-130V” model)Note: this message only seen if "3Vpn+Vr", "3Vpp+Vr" or"2Vpp+Vr" connection selectedNo VT secondary voltage for the “220-480V” model

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!