13.07.2015 Views

MiCOM P921/P922/P923 - Schneider - error

MiCOM P921/P922/P923 - Schneider - error

MiCOM P921/P922/P923 - Schneider - error

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical GuideP92x/EN FT/H42User Guide<strong>MiCOM</strong> <strong>P921</strong>/<strong>P922</strong>/<strong>P923</strong> Page 23/702.3.3 LEDS 5 to 8 configurationThe LED 5 to LED 8 configuration submenu is used to assignate to a LED aprotection function (the LED lights up when the protection function is active).To gain access to the “LED 5” submenu from the “CONFIGURATION” menu, press followed by or until the desired submenu header is displayed.To reach the LED configuration submenu press for Led 5. Press to reachLed 6, again to reach Led 7 and again to reach Led 8.CONFIGURATIONLEDLED 5 CONF.Function =NOHeading of the “CONFIGURATION” submenu. To gain accessto the CONFIGURATION menu from the default display press followed by or until the menu is displayed.Heading of the “LED” submenu.The configuration menu contains “LED 5”, “LED 6”, “LED 7” and“LED 8” submenus. These menus are identical.Description: Activate (select choice “Yes” or inhibit (“No”) LED5 operation when:- a threshold is reached,- a threshold time delay has elapsed.Refer to the following table for functions list.Range: YES/NORefer to the following table to list the protection functionsaccording to each relay.The following table lists the protection functions that can be assigned to the LEDs (5to 8) for each model of relay.Function <strong>P921</strong> <strong>P922</strong> <strong>P923</strong> FunctionVV0>, V0>>,V0>>>tV0>, tV0>>,tV0>>>X X X Instantaneous 1 st , 2 nd and 3 rd undervoltage thresholdsX X X Time delayed 1 s , 2 nd and 3 rd undervoltage thresholdsX X X Instantaneous 1 st , 2 nd and 3 rd overvoltage thresholdsX X X Time delayed 1 st , 2 nd and 3 rd overvoltage thresholdsX X X Instantaneous 1 st , 2 nd and 3 rd zero sequence voltagethresholdsX X X Time delayed 1 st , 2 nd and 3 rd zero sequence voltagethresholdsV0d>, V0d>> X X Instantaneous 1 st and 2 nd derived V0 sequence voltagethresholdstV0d>,tV0d>>X X Time delayed 1 st and 2 nd derived V0 sequence voltagethresholdsV2>, V2>> X X Instantaneous 1 st and 2 nd negative sequence overvoltagethresholdstV2>, tV2>> X X Time delayed 1 st and 2 nd negative sequence overvoltagethresholdsV1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!