P92x/EN FT/H42Page 42/70[59N] DELAY TYPE =DMT[59N] TMS=1.0[59N] tRESET V0der>=10 ms[59N] tV0der>=40 ms[59N] V0der>>=NO[59N] V0der>>=5.0 V[59N] tV0der>>=40 ms[59N] V0der>>>=NO[59N] V0der>>>=5.0 V[59N] tV0der>>>=40 msTechnical GuideUser Guide<strong>MiCOM</strong> <strong>P921</strong>/<strong>P922</strong>/<strong>P923</strong>Description: selection of the time delay characteristicRange: definite time (DMT) / inverse definite time (IDMT)Description: time multiplier setting.Range: 0.5 – 100, step = 0.5Note: this message only seen if “IDMT” time delay selectedDescription: reset time for the first derived V0 sequenceovervoltage stageRange: 0 – 100s, step = 0,01sNote: this message only seen if “IDMT” time delay selectedDescription: time delay setting for a definite time curve.Range: 0 – 599.99s, step = 0.01sNote: this message only seen if “DMT” time delay selected<strong>P922</strong> and <strong>P923</strong> onlyDescription: activation of the 2nd derived V0 sequenceovervoltage stageRange: YES/NONote: if disabled (« NO » selected), all the following messagesare invisible, until « V0der>>> » message.Description: setting of the 2nd derived V0 sequenceovervoltage stageRange: range 57-130V: 0.5 – 130V, step =0,1Vrange 220-480V: 2 – 480V, step = 0,5VDescription: time delay setting for a definite time curve.Range: 0 – 599.99s, step = 0.01sNote: definite time delay only for this stageDescription: activation of the 3rd derived V0 sequenceovervoltage stageRange: NO / AND / ORNote: if disabled (« NO » selected), all the following messagesare invisible, until the heading of the submenu.Description: setting of the 2nd derived V0 sequenceovervoltage stageRange: range 57-130V: 0.5 – 130V, step =0.1Vrange 220-480V: 2 – 480V, step = 0.5VDescription: time delay setting for a definite time curve.Range: 0 – 599s, step = 0.01sNote: definite time delay only for this stage2.6.4 Negative sequence overvoltage protection (<strong>MiCOM</strong> <strong>P922</strong> and <strong>P923</strong>)The relay will trip according to an inverse characteristic or a definite timecharacteristic for the first stage and according to a definite time characteristic for thesecond stage.The inverse characteristic is given by the following formula:t = K / (M - 1)Where,K = Time Multiplier Settingt = operating time in secondsM = Applied input voltage / Relay setting voltage (Vs).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!