13.07.2015 Views

N5161A/62A/81A/82A/83A MXG Signal Generators User's Guide

N5161A/62A/81A/82A/83A MXG Signal Generators User's Guide

N5161A/62A/81A/82A/83A MXG Signal Generators User's Guide

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Signal</strong> Generator OverviewFront Panel Overview – <strong>N5161A</strong>/<strong>62A</strong> <strong>MXG</strong> ATE2. Power Switch and LEDsThis switch selects the standby mode or the power on mode. In the standby position, the yellow LEDlights and all signal generator functions deactivate. The signal generator remains connected to theline power, and some power is consumed by some internal circuits. In the on position, the green LEDlights and the signal generator functions activate.3. LAN LEDThe LAN LED is used to indicate the LAN status.• If the LED is off, the LAN is down.• If the LED is blinking, the LAN is being configured (1.2 second duty cycle).• A 400ms duty cycle indicates the instrument has been placed into LAN Identify mode. (Refer to:INPut:LAN[:SET]:IDENtifier command).• If the LED is solidly lit, the LAN is up and functional.• If the LED fails to function, refer to the Service <strong>Guide</strong>.4. 1588 LEDThe 1588 LED indicates when the instrument is locked to an external 1588 clock.• If the 1588 green LED is on, a 1588 signal has been detected on the TRIG OUT BNC on the rearpanel.• If the 1588 green LED is off, no 1588 signal is detected on the TRIG OUT BNC on the rear panel.• If the LED fails to function, refer to the Service <strong>Guide</strong>.5. ERROR LEDThe ERROR LED indicates when there are unread errors in the error queue.• If Auto reboot is disabled, the LED will blink when an exception occurs during power up.• If the LED fails to function, refer to the Service <strong>Guide</strong>.6. LAN Reset HardkeyNOTEThis hardkey is enabled for fail–safe and diagnostic mode and should rarely be used. If theLAN Reset hardkey has been pressed and then the power is cycled on the instrument, theweb- server will be enabled after reboot.The LAN Reset is used to access the diagnostics mode during power up.• Refer to the SCPI Command Reference for equivalent remote commands.• If the LAN Reset fails to function, refer to the Service <strong>Guide</strong>.10 Agilent <strong>N5161A</strong>/<strong>62A</strong>/<strong>81A</strong>/<strong>82A</strong>/<strong>83A</strong> <strong>MXG</strong> <strong>Signal</strong> <strong>Generators</strong> User’s <strong>Guide</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!