13.07.2015 Views

Manual Samsung SCU-VAC/VAC1 Positioning System

Manual Samsung SCU-VAC/VAC1 Positioning System

Manual Samsung SCU-VAC/VAC1 Positioning System

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Communication Method SettingsSelect a communication method for the camera.Function ON OFF#5 Transfer Mode Switch RS-422(4Wire) RS-485(2Wire)Communication Response SettingsSelect a communication response method for the camera and controller: Response or No Response.Function ON OFF#6 Response Mode Switch Response No ResponseTermination Settings● CONNECTION & INSTALLATIONTo prevent the attenuation of communication signals between the camera and controller, the items atthe end of line must be set up with the termination settings.Camera Input Position #7 #8Terminal Resistance TX ON OFFTerminal Resistance RX OFF ONI When terminating for RS-485: #8 ONWhen terminating for RS-422: #7, #8 ONInitializeInitialize the system using the Initialize switch on the rear of the product.Once initialized, all current settings will return to the factory default.InitializeDo not use initialization#10 ON OFFI If you do not set the Reset witch to OFF after resetting the system, all stored data will be lost when you restart thesystem.English - 19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!