User Manual MV1-D1312(I) CameraLink®Series - Machine Vision
User Manual MV1-D1312(I) CameraLink®Series - Machine Vision
User Manual MV1-D1312(I) CameraLink®Series - Machine Vision
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
3 Product Specification<strong>MV1</strong>-<strong>D1312</strong>(I)-40 <strong>MV1</strong>-<strong>D1312</strong>(I)-80 <strong>MV1</strong>-<strong>D1312</strong>(I)-160Exposure Time 10 µs ... 1.68 s 10 µs ... 1.68 s 10 µs ... 0.41 sExposure time increment 100 ns 50 ns 25 nsFrame rate 3) ( T int = 10 µs) 27 fps 54 fps 108 fpsPixel clock frequency 40 MHz 40 MHz 80 MHzPixel clock cycle 25 ns 25 ns 12.5 nsCamera taps 1 2 2Read out modesequential or simultaneousTable 3.3: Model-specific parameters (Footnote: 3) Maximum frame rate @ full resolution)<strong>MV1</strong>-<strong>D1312</strong>(I)-40 <strong>MV1</strong>-<strong>D1312</strong>(I)-80 <strong>MV1</strong>-<strong>D1312</strong>(I)-160Operating temperature 0°C ... 50°CCamera power supply +12 V DC (± 10 %)Trigger signal input range+5 .. +15 V DCMax. power consumption < 2.5 W < 3.0 W < 3.3 WLens mountC-Mount (CS-Mount optional)Dimensions 60 x 60 x 40 mm 3MassConformityTable 3.4: Physical characteristics and operating ranges265 gCE / RoHS / WEEFig. 3.2 shows the quantum efficiency and the responsivity of the A1312 CMOS sensor,displayed as a function of wavelength. For more information on photometric and radiometricmeasurements see the Photonfocus application notes AN006 and AN008 available in thesupport area of our website www.photonfocus.com.16