TECHNICAL DATA<br />

FASTENER SELECTOR FOR WOOD FRAMING<br />

Nail Type Length Wallboard Type Thickness<br />

GWB-54 [Annular Ring 1/4" 1 1/4" (31.8 mm) Regular or Foil-back 3/8" (9.4 mm),<br />

(6.4 mm) head, 098 Dia. shank] 1 3/8" (34.9 mm) gypsum board. 1/2" (12.7 mm)<br />

<strong>Gypsum</strong> Wallboard Nail (Coated Nail length should Regular, Foil-back or Fire-Shield 1/4" (6.4), 3/8" (9.4 mm)<br />

cooler, flat head, diamond point) be sufficient (type X) gypsum board. 1/2" (12.7 mm),<br />

for 7/8" (22.2 mm) penetration<br />

5/8" (15.9 mm),<br />

into the framing member. 1" (25.4 mm)<br />

Where a certain degree of fire resistance is required for gypsum board assemblies and construction, nails of same<br />

or larger length, shank diameter, and head bearing area as those described in the fire test report must be used.<br />

Screws Type W 1 1/4" (31.8 mm) Regular or Foil-back. 3/8" (9.4 mm), 1/2" (12.7 mm),<br />

5/8" (15.9 mm)<br />

Staples US Std. 16 gauge 1" long (25.4 mm) Only in first 3/8" (9.4 mm)<br />

7/16" (11.1) crown with 1 1/8" (28.6 mm) layer of multi- 1/2" (12.7 mm)<br />

divergent points 1 1/4" (31.8 mm) layer application. 5/8" (15.9 mm)<br />

DETAILS<br />

Maximum Framing Spacing<br />

For Single-Layer <strong>Gypsum</strong> Wallboard<br />

CEILING DETAIL<br />

PLATE<br />

JOIST<br />

OUTSIDE CORNER<br />

CORNERBEAD<br />

PLATE<br />

<strong>Gypsum</strong> Board <strong>Gypsum</strong> Board Maximum<br />

Thickness Orientation Framing Spacing<br />

to Framing<br />

Ceilings:<br />

3/8" (9.5 mm) A Perpendicular B 16" (406 mm) o.c.<br />

1/2" (12.7 mm) Parallel B 16" (406 mm) o.c.<br />

1/2" (12.7 mm) Perpendicular B 24" (610 mm) o.c.<br />

5/8" (15.9 mm) Parallel 16" (406 mm) o.c.<br />

5/8" (15.9 mm) Perpendicular 24" (610 mm) o.c.<br />

Walls:<br />

STUD<br />

PLATE<br />

INSIDE CORNER<br />

3/8" (9.5 mm) Perpendicular 16" (406 mm) o.c.<br />

or Parallel<br />

1/2" (12.7 mm) Perpendicular 24" (610 mm) o.c.<br />

or Parallel<br />

5/8" (15.9 mm) Perpendicular 24" (610 mm) o.c.<br />

or Parallel<br />

SPECIFICATIONS<br />

See CSI 3-Part format Generic/Proprietary Specifications on page<br />

118.<br />

A<br />

B<br />

Shall not support thermal insulation<br />

On ceilings to receive hand or spray-applied water-based<br />

texture material either 1/2" (12.7 mm) gypsum ceiling<br />

board (ASTM C 1396/C 1396M or C 1395/C 1395M)<br />

shall be applied perpendicular to framing; other<br />

gypsum wallboard products shall be applied perpendicular<br />

to framing and board thickness shall be increased<br />

from 3/8" (9.5 mm) to 1/2" (12.7 mm) for 16" (406 mm)<br />

o.c. framing and from 1/2" (12.7 mm) to 5/8" (15.9 mm)<br />

for 24" (610 mm) o.c. framing.<br />

100 NATIONAL GYPSUM WALLBOARD PRODUCTS