Wallboard Over Masonry<br />

09 29 00/NGC<br />

BUYLINE 1100<br />

DESCRIPTION<br />

A. Z FURRING CHANNEL<br />

1. Application of Foam.<br />

Z Furring Channel is used<br />

to secure rigid insulation<br />

and gypsum wallboard<br />

boards to masonry walls.<br />

Insulation thickness (1",<br />

1 1/2", 2") determines depth<br />

of Z furring web. The<br />

channel is applied<br />

vertically and fastened to<br />

the masonry wall through<br />

the short (3/4") flange with<br />

suitable masonry fasteners<br />

24" o.c. maximum.<br />

Application is progressive.<br />

After fastening each Z<br />

Furring Channel, a 24"<br />

wide floor-to-ceiling-high<br />

insulation board is fit<br />

between the wall and the<br />

wide (1 1/4") flange.<br />

2. Application of Wallboard.<br />

Erect Gold Bond <strong>Gypsum</strong><br />

Wallboard either vertically<br />

or horizontally to the<br />

Z Furring Channels.<br />

Wallboard edges or ends<br />

that run parallel to the<br />

channels shall be centered<br />

and abutted over channels.<br />

Fasten wallboard with 1"<br />

Type S Drywall Screws<br />

spaced 12" o.c. When<br />

wallboard erection is<br />

complete, finish all joints<br />

and screw heads in<br />

accordance with ProForm<br />

Joint Finishing System.<br />

Prefinished gypsum<br />

wallboard boards may be<br />

laminated vertically to the<br />

channels with screws at top<br />

and bottom.<br />

Limitations<br />

Power driven fasteners should<br />

be used to secure furring<br />

only when wall is<br />

monolithic concrete.<br />

Regular concrete nails can<br />

be used for fastening to unit<br />

masonry. If block is old,<br />

test nailing should be done<br />

in advance to determine<br />

optimum size and type<br />

of nail.<br />

B. LAMINATION<br />

1. Application of Foam.<br />

Insulation may be urethane<br />

foam or extruded<br />

polystyrene. Expanded<br />

bead polystyrene is not<br />

recommended. For<br />

horizontal wallboard<br />

application, install wood<br />

furring strips (nominal 2"<br />

wide x 1/32" greater than<br />

the foam thickness)<br />

horizontally along the wallceiling<br />

and wall-floor<br />

angles, where horizontal<br />

wallboard joints will fall,<br />

and around door and<br />

window openings. For<br />

vertical wallboard<br />

application, furring strips<br />

are required at the<br />

horizontal wall-ceiling and<br />

wall-floor lines and around<br />

door and window<br />

openings.<br />

Masonry surface must be dry,<br />

clean and free of dust, dirt,<br />

form release agents, oil,<br />

grease or water soluble<br />

materials. Treat painted<br />

masonry as recommended<br />

for laminating to painted<br />

surfaces. Apply adhesive to<br />

the foam insulation in 3/8"<br />

dia. beads continuously<br />

around the perimeter and<br />

through the field in the long<br />

direction with the beads<br />

spaced 16" o.c. Contact<br />

adhesive manufacturer for<br />

compatability with foam.<br />

Apply the foam boards<br />

horizontally to the wall<br />

with a sliding motion and<br />

hand press entire board to<br />

ensure full contact of<br />

adhesive and wall surface.<br />

2. Application of Wallboard.<br />

ProForm All-Purpose Joint<br />

Compounds may be used.<br />

(Do not use water base<br />

compounds for laminating<br />

prefinished boards to<br />

foam.)<br />

Permanent nails or screws<br />

12" o.c. are required to<br />

fasten wallboard to wood<br />

furring. Wallboard must be<br />

installed a minimum of<br />

1/8" from the floor. Use<br />

temporary nails or bracing<br />

as necessary to hold<br />

wallboard boards in firm<br />

contact to the foam until<br />

adhesive has dried or set.<br />

Limitations<br />

1. Nails or screws used for<br />

attachment of wallboard<br />

boards to furring strips must<br />

not penetrate through the<br />

furring.<br />

2. Power driven fasteners<br />

should be used to secure<br />

furring to monolithic<br />

concrete. Regular concrete<br />

nails can be used for<br />

fastening to unit masonry. If<br />

block is old, test nailing<br />

should be done in advance<br />

to determine optimum size<br />

and type of nail.<br />

3. During cold weather, room<br />

temperature between 50˚F<br />

and 70˚F must be<br />

maintained uniformly<br />

during application and<br />

until adhesive is thoroughly<br />

dry or premises are<br />

occupied. Provide<br />

adequate ventilation.<br />

4. <strong>Gypsum</strong> wallboard is not<br />

recommended in areas<br />

DETAILS<br />

1 1 / 4<br />

"<br />

SPECIFICATIONS<br />

Z FURRING<br />

where it will be exposed to<br />

excessive moisture or<br />

continued high humidity.<br />

5. Since the use of foam<br />

plastic insulation is<br />

regulated by many building<br />

codes, consultation with<br />

local building authorities is<br />

recommended before<br />

installation.<br />

Since unprotected foam<br />

insulation may represent a<br />

fire hazard, it should be<br />

covered promptly and<br />

completely with gypsum<br />

wallboard.<br />

3 /4 "<br />

1", 1 1 / 2<br />

" ,2"<br />

See CSI 3-Part format Generic/Proprietary Specifications on<br />

page 118.<br />

09 29 00<br />

NATIONAL GYPSUM WALLBOARD PRODUCTS<br />

105