Wood Frame Walls and Ceilings/Double Layer <strong>Construction</strong><br />

DESCRIPTION<br />

09 29 00/NGC<br />

BUYLINE 1100<br />

INSTALLATION<br />

The Gold Bond double layer<br />

system consists of a face<br />

layer of gypsum board joblaminated<br />

to a base layer of<br />

gypsum wallboard, or<br />

gypsum sound deadening<br />

board applied with power<br />

driven screws or staples, or<br />

nailed to the framing in the<br />

conventional manner.<br />

DETAILS<br />

CEILING DETAIL<br />

STUD<br />

PLATE<br />

JOIST<br />

RECOMMENDATIONS<br />

DOUBLE LAYER<br />

WALLBOARD<br />

1. Base layer<br />

The first layer may be<br />

specified the same as single<br />

layer application except<br />

that fasteners shall be<br />

driven flush with the board<br />

surface and joints will not<br />

be treated. Base layer must<br />

not be secured to framing<br />

with clips.<br />

2. Adhesive Application of<br />

Face Layer, General<br />

a. All joints shall fall at least<br />

10" from parallel joints in<br />

the base layer. Adhesive<br />

shall be: (select one)<br />

b. ProForm all-purpose ready<br />

mix joint compound or<br />

Sta-Smooth setting type<br />

compound applied with a<br />

notched spreader to the<br />

back side of the finish<br />

layer.<br />

c. Adhesive is applied with a<br />

caulking gun. Align board<br />

edges. Reference ASTM<br />

C 840, section 9.<br />

OUTSIDE CORNER<br />

PLATE<br />

CORNERBEAD<br />

PLATE<br />

INSIDE CORNER<br />

3. Adhesive Application,<br />

Regular <strong>Gypsum</strong> Board<br />

The finish layer shall be<br />

positioned on the wall or<br />

ceiling within 10 minutes<br />

(unless otherwise specified<br />

above) and held in place<br />

with sufficient temporary<br />

(nails) (Type G Drywall<br />

Screws) (bracing) to ensure<br />

adequate contact and<br />

alignment of the gypsum<br />

boards. When the bond<br />

has developed (usually<br />

24 hours) the temporary<br />

(fasteners) (bracing) shall be<br />

removed. Resulting holes<br />

shall be filled flush to the<br />

surface with Joint<br />

Compound and the joints<br />

shall be finished.<br />

Cornerbead shall be<br />

applied at all exterior<br />

angles.<br />

4. Adhesive Application,<br />

Prefinished <strong>Gypsum</strong> Board<br />

a. Pre-bow board by storing<br />

overnight in such a position<br />

that the ends of each board<br />

curve away from the base<br />

layer when put in vertical<br />

mounting position.<br />

b. Apply ready-mix or Sta-<br />

Smooth joint compound in<br />

nominal 5" ribbons of four<br />

1/4" x 1/4" beads located<br />

around the perimeter and<br />

center of the boards<br />

(approximate coverage for<br />

ready-mix is 9-10 gal./1000<br />

sq.ft and Sta-Smooth is 50-<br />

60 lbs./1000 sq.ft.). An<br />

alternative is 2" diameter<br />

daubs 1 /2" thick, 16" o.c.<br />

(approximate coverage for<br />

ready-mix is 5 1/2"-6<br />

gal./1000 sq.ft. and Sta-<br />

Smooth is 30 - 35 lbs./1000<br />

sq.ft.).<br />

c. Temporarily brace, as<br />

required, to ensure proper<br />

contact and edge alignment<br />

of boards.<br />

5. Mechanical Application of<br />

Face Layer<br />

Mechanical attachment of<br />

face layer for fire or sound<br />

rated constructions shall be<br />

made in accordance with<br />

the specifications for the<br />

system selected.<br />

For non-rated construction,<br />

nails used in wood framing<br />

to supplement adhesive<br />

shall be type GWB, of a<br />

length to provide 7/8"<br />

minimum penetration into<br />

framing and shall be<br />

spaced 16" o.c. max.<br />

Screws used in wood<br />

framing shall be Type W, of<br />

a length to provide<br />

minimum 5/8" penetration<br />

into the framing and shall<br />

be spaced 24" o.c. max.<br />

If no adhesive is used,<br />

standard fastener spacings<br />

shall prevail.<br />

SPECIFICATIONS<br />

See CSI 3-Part format<br />

Generic/Proprietary<br />

Specifications on<br />

page 118.<br />

In double layer construction<br />

use any of the following<br />

appropriate laminating<br />

adhesives: (1) Sta-Smooth<br />

Compound or Sta-Smooth<br />

Lite for fast hardening;<br />

(2) All-Purpose Joint<br />

Compound for spreading<br />

on the back surface of the<br />

finish layer boards: (3)<br />

drywall adhesive meeting<br />

ASTM C 557.<br />

Base layer is applied on<br />

ceilings, then sidewalls,<br />

secured with 1 1/4" Type<br />

W Screws 12" o.c. on<br />

ceilings, 16" o.c. on walls;<br />

nails located 7" o.c. on<br />

ceilings; 8" o.c. on<br />

sidewalls; staples 5" o.c. on<br />

ceilings and 6" o.c. on<br />

sidewalls.<br />

Finish layer is temporarily<br />

nailed or braced until<br />

adhesive dries. On walls,<br />

prefinished boards, applied<br />

vertically, can be prebowed,<br />

nailed just top and<br />

bottom.<br />

RECOMMENDATIONS<br />

1. Double layer wallboard<br />

application over wood<br />

framing is recommended<br />

for the ultimate in wall<br />

surfacing and in areas<br />

where increased fire<br />

protection and better sound<br />

insulation are desired<br />

between rooms. (For test<br />

results see pages 13-14 of<br />

this guide.) Custom built<br />

homes, commercial<br />

buildings and party walls<br />

between apartments would<br />

be considered appropriate<br />

areas for double layer<br />

application.<br />

09 29 00<br />

NATIONAL GYPSUM WALLBOARD PRODUCTS<br />

101