Solid Laminated Partitions<br />

09 29 00/NGC<br />

BUYLINE 1100<br />

DESCRIPTION<br />

DETAILS<br />

Laminated Partitions have<br />

been developed for use<br />

where sturdy, nonloadbearing<br />

walls are desired.<br />

The total thickness is<br />

nominal 2". 1" Fire-Shield<br />

Shaftliner is used with face<br />

layers of gypsum board.<br />

PHYSICAL PROPERTIES<br />

A. Fire Resistance. Fire<br />

endurance ratings have<br />

been established as<br />

follows: 1 Hour (1/2"<br />

Regular <strong>Gypsum</strong> board<br />

face boards, ProForm<br />

BRAND Sta-Smooth joint<br />

compound* as laminating<br />

compound -Test, FM<br />

Design WP 671-1 hr.); 2<br />

Hours (1/2" Fire-Shield C<br />

Wallboard face boards,<br />

ProForm BRAND Sta-Smooth<br />

joint compound* as<br />

laminating compound -<br />

Test, FM Design WP 668-2<br />

hr. or UL U525).<br />

B. Sound Isolation. An STC<br />

rating of 34 has been<br />

achieved in tests conducted<br />

in accordance<br />

with ASTM E 90.<br />

TECHNICAL DATA<br />

C. Economical. The laminated<br />

partition offers a substantial<br />

saving in installation time<br />

and subsequently in labor<br />

costs over other types of<br />

solid partitions. The 1"<br />

gypsum core is quickly and<br />

easily installed and the<br />

large sheets of gypsum<br />

wallboard provide a dry<br />

finish surface in minimum<br />

time.<br />

LIMITATIONS<br />

The laminated partition is<br />

adapted to any type of<br />

building for nonloadbearing<br />

partitions not<br />

exceeding 12' in height.<br />

Further limitations to height<br />

are based on the partition<br />

length in the table below.<br />

*Required for fire rating.<br />

Maximum<br />

Partition Length<br />

Ceiling Height<br />

Between Restraints<br />

12' (3658 mm) 14' (4267 mm)<br />

11' (3353 mm) 20' (6096 mm)<br />

10' (3048 mm) Over 20' (6096 mm)<br />

JOINT<br />

COMPOUND<br />

ADHESIVE<br />

FLOOR LINE<br />

WALLBOARD CORNERBEAD<br />

12d NAIL/12" O.C.<br />

1" FIRE-SHIELD SHAFTLINER<br />

TAPE AND JOINT<br />

COMPOUND<br />

1" FIRE-SHIELD SHAFTLINER<br />

WALLBOARD<br />

CORNER WALL DETAIL<br />

09250U<br />

Scale: 3" = 1'-0"<br />

WALLBOARD<br />

BASE<br />

VERTICAL SECTION USING<br />

METAL FLOOR RUNNER<br />

09250T<br />

Scale: 3" = 1'-0"<br />

1" FIRE-SHIELD<br />

SHAFTLINER<br />

L FLOOR<br />

RUNNER<br />

09 29 00<br />

CAULKING<br />

1/4"<br />

1" FIRE-SHIELD SHAFTLINER<br />

CASING BEAD<br />

L RUNNER<br />

ANCHORAGE TO CONCRETE<br />

CEILINGS, WALLS OR COLUMNS<br />

09250V<br />

Scale: 3" = 1'-0"<br />

NATIONAL GYPSUM WALLBOARD PRODUCTS<br />

107