Firmware on the <strong>Call</strong> Recording Box<br />

Sense Version 2.4.1 and above requires the firmware 2.4.1 dated June 2010 to be installed on the<br />

call recording unit. If the firmware on the box is older than 2.4.1 / June 2010 then it can be upgraded.<br />

Checking The Firmware Version<br />

To establish what firmware a recorder is running, on the call recording server the locate the \bin folder<br />

and double click the ‘Stop Service’ icon a black window will appear and then close down. Now double<br />

click the vps.exe icon, a black window will appear and the firmware version is displayed in the lower<br />

section of the vps window. If the date is older than Jun 11 2010 then the firmware on the box should<br />

be upgraded.<br />

If the firmware version is from any date in 2008, then it’s not possible to upgrade the firmware on the<br />

box and it should be returned to NEC using the normal returns procedure. A replacement box will be<br />

made available that will have the 2.4.1 / June 11 2010 firmware already installed.<br />

If there are multiple units attached to a PC then the firmware version for each box should be checked<br />

individually. To select a box, type ‘SDD 0’ to select the first box detected by the PC, you will see a<br />

confirmation in the lower section of the vps window that you are on box 0. To view the firmware<br />

version on the box, type ‘reset’ and press enter, the box will restart and the firmware version will be<br />

displayed.<br />

To switch to the next box, type ‘SDD 1’ the box can be restarted in the same way to see the firmware<br />

version running on the box. The SDD number can be incremented by 1 each time to check the<br />

firmware version on each box connected to the PC. On a PC with 4 call recorders connected to it, the<br />

firmware would have to be checked for SDD 0, SDD 1, SDD 2 and SDD 3.