Upgrading the Firmware<br />
To upgrade the firmware where you have a single call recording unit, there should be a file called<br />
firmware.bin in c:\ on the PC running the call recording software. When the sense software is<br />
unzipped there a copy of the firmware file in the c:\sense2.4.1 folder, the file is called<br />
firmware2.4.1.110610.bin, this should be renamed to firmware.bin and copied to c:\ . When the<br />
firmware file is correctly named and in c:\, then type ‘burn’ in the vps window. The upgrade will now<br />
commence and takes around 1 minute, once completed, you will see ’Download succeeded’ in the<br />
vps window.<br />
Once you see the Download Succeeded message type ‘reset’ and press enter to reset the box. As<br />
the box boots up, you will see the new firmware version displayed in the vps window. If you have<br />
multiple boxes each box has to be upgraded in turn. To select the first box, type SDD 0 and upgrade<br />
the firmware as above. Once upgraded, select the next box by typing ‘SDD 1’ and carry out the<br />
upgrade procedure. Repeat this for each box by incrementing the SDD for each box a required.<br />
Once all boxes have been upgraded, double click the start service icon from the \bin folder