27.09.2018 Views

AHG Solutions Guide_Edition 2.7

Full Product and Solutions Guide - Automatic Heating Global Pty Ltd

Full Product and Solutions Guide - Automatic Heating Global Pty Ltd

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Contents<br />

Vacuum Deaerators - Dirt and Air Separation<br />

Installation Examples<br />

Servitec<br />

Air Discharge ≥ 500<br />

LSL<br />

Control<br />

Unit<br />

Reflex Fillset<br />

PIS<br />

TIME<br />

Water<br />

Make-up<br />

Duraflex Vacuum Deaerator in magcontrol mode combined with expansion vessel system<br />

Reflex Fillset<br />

Water<br />

Make-up<br />

Reflex G<br />

Expansion<br />

Vessel<br />

Max. 70 ºC<br />

Discharge<br />

valve<br />

Boiler/Chiller<br />

heating&<br />

cooling source<br />

PIS<br />

Filling - Make-Up,<br />

Pressure-Dependent-<br />

Magcontrol<br />

The pressure is shown in the display<br />

Excess and insufficient pressure<br />

levels are signaled Automatic,<br />

controlled make-up in the event that<br />

the system fails to reach the filling<br />

pressure of 0.2 bar Duraflex Vacuum<br />

Deaerator degassing of the make-up<br />

and filling water.<br />

TIME<br />

Degassing<br />

Vacuum degassing of a part flow<br />

of the circuit water takes place<br />

according to an optimized schedule<br />

using a selectable degassing mode.<br />

• Continuous degassing<br />

(after start-up)<br />

• Interval degassing<br />

(automatically activated after<br />

continuous degassing)<br />

EXPANSION &<br />

DEAERATION<br />

Servitec<br />

Air Discharge<br />

≥ 500<br />

LIS<br />

RG primary vessel<br />

RS control unit<br />

Water Make-up, Level-<br />

Dependent Levelcontrol<br />

LSL<br />

PIS<br />

TIME<br />

Max. 70 ºC<br />

PIS<br />

Solenoid<br />

valve<br />

Compressor<br />

Automatic, controlled water makeup<br />

if the minimum water level is not<br />

reached in the expansion vessel of<br />

the compressor controlled pressure -<br />

maintaining station Duraflex Vacuum<br />

Deaerator degassing of the make-up<br />

water<br />

Control<br />

Unit<br />

Flex duct<br />

LIS<br />

Discharge valve<br />

Duraflex Vacuum Deaerator in levelcontrol mode for systems with compressor controlled pressure maintaining station<br />