Chapter 6: Troubleshooting<br />

6666<br />

Cause code Description Event<br />

15D2 CES → NCS<br />

Signaling only.<br />

15E1 Preemption -<br />

circuit reserved<br />

for reuse.<br />

1651 No<br />

circuit/channel<br />

available.<br />

1661 Recovery on timer<br />

expiry.<br />

16C1 Reserved<br />

16C2 Recovery on timer<br />

expiry.<br />

LES is clearing this MES ID and<br />

channel number in the busy lists at<br />

LES and NCS because a new call<br />

to/from this MES is being set-up (and<br />

thus any previous call to/from this<br />

MES must have cleared).<br />

LES is attempting to clear an MES<br />

which h<strong>as</strong> sent an SCPC channel<br />

rele<strong>as</strong>e message but is found still to be<br />

transmitting 5.12 s later.<br />

LES is rejecting the call because an<br />

appropriate channel unit is not<br />

currently available at this specific LES.<br />

LES is clearing the call because of an<br />

interruption in reception of the MES<br />

carrier exceeding the allowed time<br />

limit.<br />

LES is clearing the call because an<br />

appropriate SCPC MES carrier h<strong>as</strong> not<br />

been received by the LES (at the<br />

commencement of the call) within the<br />

allowed time limit.<br />

1790 LES is clearing the call because of a<br />

malfunction in the credit card validity<br />

checking datab<strong>as</strong>e or in the<br />

communications links thereto.<br />

List of Error messages 149<br />