Chapter 3: Getting started<br />
Note If a Distress LES is not defined for each Ocean Region, an alarm<br />
will appear and the entry ‘Distress LES is not selected in all<br />
Ocean Regions’ will be added to the alarm log.<br />
To cancel the Distress mode, press and hold the Distress Stop button, after<br />
the button light becomes constant, but before the 15 seconds timer runs<br />
out. The display will then show Distress Aborted.<br />
If the Distress call is continued, the handset will display DISTRESS -<br />
Calling. The call will be connected to the RCC, the handset will display<br />
DISTRESS - Connected and the cradle LED ‘Priority call’ will light<br />
up. You can now make the Distress call<br />
3. Use the handset to talk to the RCC operator.<br />
The ‘Distress’ button light will stay on until the call is aborted.<br />
Distress call failure. 3.4.3<br />
If the Distress call fails to connect due to a system malfunction (BDU, ADU,<br />
satellite or terrestrial), the light in the cradle ‘Distress’ button will turn off and<br />
the system will return to a normal state.<br />
Distress and Priority call to the ship 3.4.4<br />
The RCC operator can generate a distress alert priority call to the ship. The<br />
‘Priority Call’ LED will start fl<strong>as</strong>hing on all cradles, and if the call h<strong>as</strong> distress<br />
priority the buzzer will beep with 1 second intervals. Any calls with lower<br />
priority, including MPDS sessions, are preempted and a busy tone is heard.<br />
Answer the distress and priority call by picking up a handset or by pressing<br />
after which the ‘Priority Call’ LED will light steadily and the buzzer stops<br />
beeping.<br />
The ‘Priority Call’ LED is turned off when the call is terminated.<br />
If the call is not answered by the ship, but terminated by the RCC, the Alarm<br />
LED turns on to indicate that there w<strong>as</strong> an unanswered distress alert or priority<br />
call. Details about the alarm can be checked in the alarm log.<br />
44 Distress call