TABLE K.1 (Cont.)<br />

Variance<br />

Variance<br />

Regul<strong>at</strong>ion<br />

Regul<strong>at</strong>ion<br />

ID St<strong>at</strong>e Granted C<strong>at</strong>egory<br />

Description<br />

Summary<br />

Cit<strong>at</strong>ion<br />

206 IL Yes Other Variance to allow piping th<strong>at</strong> does not The regul<strong>at</strong>ion establishes limiting-value 35 Ill. Adm. Code, Subtitle C,<br />

(standards for comply with the sewage works standards to criteria for the design and prepar<strong>at</strong>ion of Chapter II, Part 370<br />

sewage be installed.<br />

plans and specific<strong>at</strong>ions for wastew<strong>at</strong>er<br />

works)<br />

collection and tre<strong>at</strong>ment systems, to<br />

promote uniformity of practice throughout<br />

the St<strong>at</strong>e.<br />

226 IN Yes Closure/ Variance to allow use of ash, ash/soil Final compacted cover must have 6 in. of 329 IAC 10-30-2<br />

post-closure mixture, and 40-mil linear low-density topsoil plus 2 ft of compacted clay for<br />

requirements polyethylene (LLDPE) as final cover, slopes less than 15% or 3 ft of compacted<br />

r<strong>at</strong>her than compacted soil, as the<br />

regul<strong>at</strong>ions specify.<br />

clay for slopes gre<strong>at</strong>er than 15%.<br />

222 IN Yes Cover/dust Variance waiving intermedi<strong>at</strong>e cover Must apply and compact no less than 6 in.<br />

controls otherwise required by the regul<strong>at</strong>ions. of cover over all exposed solid waste<br />

monthly regardless of we<strong>at</strong>her conditions,<br />

or annually, if the solid waste can be<br />

demonstr<strong>at</strong>ed to have an in-place<br />

permeability of less than 1 × 10-6 329 IAC 10-28-12(b) (Type II);<br />

cm/s.<br />

329 IAC 10-36-12 (Type III)<br />

223 IN Yes Closure/ Variance allowing use of 2.5 ft of fine 329 IAC 10-37-2 requires 2 ft of soil as 329 IAC 10-37-2;<br />

post-closure sandy loam soils for the final cover, r<strong>at</strong>her described in 329 IAC 10-36-11, and 6 in. of 329 IAC 10-36-11;<br />

requirements than 2 ft of soil of Unified Soil<br />

veget<strong>at</strong>ive topsoil as required by 329 IAC 329 IAC 10-37-4(b)(4)<br />

Classific<strong>at</strong>ion ML, CL, MH, CH, or OH<br />

and 6 in. of veget<strong>at</strong>ive topsoil, as specified<br />

in the regul<strong>at</strong>ions.<br />

10-37-4.<br />

226 IN Yes Cover/dust Variance to allow use of Soil-Sement<br />

controls<br />

® , a Intermedi<strong>at</strong>e cover of not less than 1 ft of 329 IAC 10-28-12(a)(3)<br />

polymer-based m<strong>at</strong>erial, as an intermedi<strong>at</strong>e compacted clay-type soil must be applied<br />

cover, r<strong>at</strong>her than 1 ft of clay-type soil, as to any area within a Type I restricted waste<br />

the regul<strong>at</strong>ions specify.<br />

landfill th<strong>at</strong> has not received waste for<br />

90 days or more.<br />