<strong>DK</strong><strong>16</strong> KDCU,<br />

CKTl<br />

- OR-<br />

<strong>DK</strong><strong>16</strong> P<strong>DK</strong>U,<br />

CKTl<br />

-OR-<br />

<strong>DK</strong><strong>16</strong> DIGITAL<br />

CKT5 OF<br />

BASE UNIT<br />

-OR-<br />

<strong>DK</strong>8 KSU,<br />

CKT 3 AND 4<br />

DDCB<br />

TO CUSTOMER<br />

INSTALLATION-PERIPHERALS<br />

SECTION 100-8<strong>16</strong>-207<br />

MARCH 1993<br />

DOOR PHONE<br />

DOOR PHONE B<br />

DOOR PHONE<br />

DDCB TO <strong>DK</strong>8 KSU WIRING CHART DDCB TO <strong>DK</strong><strong>16</strong> BASE UNIT WIRING CHART<br />

03 DT (32) / DR (7) ;; PIN 3 I4<br />

PT (33) / PR (8) PIN 5 I6<br />

NOTES<br />

1. Relay control contact will close when the door phone is in the<br />

ringing, talk, or monitor state.<br />

2. See Paragraph 4.25 for Door Lock assignments.<br />

3. Relay contact specifications are -24 VDC at 1 .O amp. max. Do<br />

not connect relay contacts to 120 AC commercial power.<br />

-.A..-- - -<br />

FItiUHt 7-Y<br />

<strong>DK</strong>8 AND <strong>DK</strong><strong>16</strong> DOOR LOCK CONTROL OPTION (DDCB)<br />

5) Access Programs 29-1 - 29-2 to program a<br />

Night Transfer button (NT1 or NT2) on all<br />

DSS consoles that are to transfer the system<br />

into the NIGHT mode.<br />

I<br />

BASE UNIT<br />

AMPHENOL<br />

TO DDCB KSU JACK<br />

TO PIN 3/4<br />

PT (35) / PR (10) TO PIN 5/6<br />

DDCB TO <strong>DK</strong><strong>16</strong> EXPANSION UNIT<br />

WIRING CHART<br />

See Figure 8-4 for <strong>DK</strong><strong>16</strong> Base Unit, P<strong>DK</strong>U, and<br />

KCDU pin-out information<br />

7B) Solder the jumper W2 on the PIOUS to the<br />

MAKE or BREAK position, as required:<br />

l MAKE-Shorts the normally open con-<br />

tacts (NHT and NHR) when the night<br />

relay is activated.<br />

6) If tenant operation is required, access Program l BREAK-Opens the normally closed<br />

15 to set the CO lines for tenant 1 (NM) or contacts (NHT and NHR) when night<br />

tenant 2 (NTZ) operation. relay is activated.<br />

7A) Set the PI1 jumper plug on the PIOU to the<br />

MAKE or BREAK position, as required:<br />

l MAKE-Shorts the normally open con-<br />

tacts (pins 9 and 34) when the night relay<br />

is activated.<br />

l BREAK-Opens the normally closed<br />

contacts (pins 9 and 34) when the night<br />

relay is activated.<br />

7-11<br />

8) Refer to Figures 7-6 and 7-7 for wiring/inter-<br />

connecting details. Connect the PIOU or PI-<br />

OUS to the MDF as required for the night relay<br />

function.<br />

NOTE:<br />

Door phones programmed to ring over externalpage<br />

in night mode (Program 77-l) do not<br />

activate the NT relay.<br />

I