TABLE 1 -E<br />

PROGRAM 03<br />

SLOT ASSIGNMENTS<br />

(<strong>DK</strong><strong>16</strong> ONLY)<br />

Step<br />

Press...<br />

BUHONS + LED keys<br />

# Action description LCD RESPONSE . . .<br />

PROGRAMMING PROCEDURES-INTRODUCTION<br />

SECTION 100-8<strong>16</strong>-301<br />

MARCH 1993<br />

1. Use an LCD digital or electronic telephone with a NO. OF STATION (10 - 29)<br />

programming template.<br />

JAN 20 SUN 06:43<br />

2. *.#*#1*2*3 PROGRAM MODE<br />

Enter programming mode.<br />

3. SPKR 0 3 HOLD PROGRAM = 03<br />

Access Program 03. After SPKR key is pressed, system DATA STORE<br />

beeps to indicate program number may be entered.<br />

4. SPKR 03 SELECT =<br />

Prepare system for a selection.<br />

5. Enter a PCB slot number (00-07). 03 SELECT = (00 - 07)<br />

CARD = Default code will<br />

The system defaults as follows: appear here<br />

00<br />

Initialized data assigns CTU slot 00 to be non-optioned,<br />

03 SELECT<br />

CARD = 91<br />

= 00<br />

-SLOT NUMBER<br />

without a K4RCU.<br />

01<br />

Initialized data assigns <strong>DK</strong>U slot 01 to be non-optioned<br />

03 SELECT<br />

CARD = 61<br />

= 01<br />

-SLOT NUMBER<br />

without a door phone or DDSS console.<br />

02 03 SELECT = 02<br />

-SLOT NUMBER<br />

Initialized data assigns fixed KCOU slot 02 with code Il. CARD = 11<br />

03<br />

Initialized data assigns fixed KSTU slot 03 with code 31.<br />

03 SELECT<br />

CARD = 31<br />

= 03<br />

-SLOT NUMBER<br />

04-07<br />

Initialized data assigns Expansion Unit’s universal slots<br />

03 SELECT<br />

CARD = 00<br />

= 04 - 07.<br />

LSLOT NUMBER<br />

04 - 07 to be empty, code 00.<br />

6. 00-92 03 SELECT = (00 - 07)<br />

Dial the PCB code recorded on the record sheet. CARD = (00 - 92)<br />

Refer to the PCB code reference table on Program 03<br />

System Record Sheet for a definition of the codes.<br />

7. HOLD 03 SELECT = (00 - 07)<br />

Secure data in system programming. DATA PROGRAMMED<br />

8. SPKR 03 SELECT =<br />

Prepare system for another selection (go back to<br />

step 5), or exit Program 03 (continue with step 9).<br />

9. # # HOLD 03 SELECT = ##<br />

Secure Program 03 data in system memory. DATA PROGRAMMED<br />

10. SPKR PROGRAM =<br />

Exit Program 03. Enter another program number, or exit<br />

programming mode (go to step 11).<br />

System beeps to indicate it’s exiting Program 03.<br />

11. # # HOLD NO. OF STATION (10 - 29)<br />

Exit programming mode. JAN 20 SUN 06:58<br />

12. In order to secure Program 03 entries, POWER OFF<br />

for 5 seconds, then POWER ON.<br />

l-11