INSTALLATION-PERIPHERALS<br />

SECTION 100-8<strong>16</strong>-207<br />

MARCH 1993<br />

b) Type A T H from the PC keyboard used<br />

in step 5a.<br />

l PC 1 and PC 2 screens both display,<br />

NO CARRIER.<br />

l The Data Call LEDs on each <strong>DK</strong>Tare<br />

Off.<br />

XXX = PDIU-DI escape sequence (see<br />

Paragraph 10.63)<br />

10.83 PC to Printer Test Call Using <strong>Manual</strong><br />

Dialing (see Figure 7-35)<br />

1)<br />

2)<br />

DIU Programming:<br />

l Program 20: Port 01. LEDs 01,02, and<br />

17 ON; all other LEDs OFF.<br />

l Program 20: Port 03. LEDs 01,04, and<br />

17 ON; all other LEDs OFF.<br />

l Program 39: Port 01. Data Call (56) and<br />

Data Release (54) buttons should be<br />

provided.<br />

l Default settings for PDIU-DI, S-Regis-<br />

ters.<br />

normally accomplished using the DOS and<br />

MODE commands.<br />

3) Using the manufacturer’s documentation,<br />

make sure the communication parameters<br />

(data speed, parity, data bits, stop bits, etc.) of<br />

the PC COM port match the printer’s serial<br />

interface parameters.<br />

4) To connect the PC to the printer, press the<br />

<strong>DK</strong>T’s Data Call button and dial 1 3.<br />

l The CONNECT on the PDIU-DS will be<br />

lit.<br />

l The connection between the PC and the<br />

printer is completed, as shown by the<br />

thick lines above (PDIU-DS 13 is in the<br />

communication mode).<br />

l If busy tone is sent to the <strong>DK</strong>T, the<br />

connection is not complete; press Data<br />

Release and try step 4 again.<br />

5) Operate the PC to print data as required.<br />

Make sure the PC is configured to print data<br />

from its serial COM port (the PC COM port 6) To terminate the call, press the <strong>DK</strong>T’s Data<br />

connected to <strong>DK</strong>T/PDIU-DI port 01). This is Release button.<br />

RS-23: 2<br />

RS-232<br />

FIGURE 7-35<br />

<strong>DK</strong>8 AND <strong>DK</strong><strong>16</strong> PC TO PRINTER TEST CALL USING MANUAL DIALING<br />

7-52<br />

6