p-jP~~~(HI-(~~~-~~-~I-~-~<br />

PROGRAMMINGPROCEDURES-INSTRUCTIONS/SYSTEMRECOROS<br />

SECTION lOO-8<strong>16</strong>-302<br />

MARCH1993<br />

PROGRAM48<br />

STATION TOLL RESTRICTION CLASSIFICATION<br />

SELECT = Logical Port Number(s)<br />

Enter the port number(s)<br />

station(s) being defined.<br />

See Note 3 for entering<br />

of the<br />

a range.<br />

-71<br />

Digit Restriction Code 0 or 1<br />

Enter 0 for no digit restriction.<br />

Station Restriction Code (0 - 6)<br />

Enter 0 for No Station Toll Restriction.<br />

Enter 1 for Area Code Toll Restriction.<br />

Enter 1 for digit restriction. Enter 2 for Area Code Toll Restriction ) i<br />

NOTE: Shaded areas apply to <strong>DK</strong><strong>16</strong> only<br />

14<br />

15<br />

<strong>16</strong><br />

17<br />

18<br />

19<br />

204<br />

NOTES:<br />

1. For more information, see the instructions preceding the record sheets.<br />

2. Initialized data reads “10” for all ports.<br />

3. A range of ports may be entered:<br />

- -<br />

Low port in range J L High port in range<br />

4. <strong>DK</strong>8, Port 10 and <strong>DK</strong><strong>16</strong>, Port 20 assigns DISA CO lines to a Toll Restriction<br />

Classification.<br />

2-109<br />

and 0 or 1 as 1st or2nd digit.<br />

Enter 3 for Class 1 Toll Restriction.<br />

Enter 4 for Class 2 Toll Restriction.<br />

Enter 5 for Class 3 Toll Restriction.<br />

Enter 6 for Class 4 Toll Restriction.