PROGRAMMING PROCEDURES-INSTRUCTIONS/SYSTEM RECORDS<br />

SECTION 100-8<strong>16</strong>-302<br />

MARCH 1993<br />

PROGRAM 37<br />

RING TRANSFER (CAMP-ON) RECALL TIME<br />

SELECT = Logical Port Number (00-19) 1 L HOLD T/ME = Ring Transfer Recall Time<br />

Enter the number of the port that Enter the Ring Transfer Recall<br />

needs a Ring Transfer Recall time Time (in seconds). The acceptable<br />

assigned. See Note 3 for range is 011 - 999 seconds. Use<br />

entering a range of ports. three digits.<br />

NOTE: Shaded areas apply to <strong>DK</strong><strong>16</strong> only<br />

L;$y’ 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15<br />

Hold<br />

Time<br />

NOTES:<br />

1. For more information, see the instructions preceding the record sheets.<br />

2. Initialized data assigns a Ring Transfer Recall Time of 032 seconds to all ports.<br />

3. To enter a range ofports, key in the sequence:<br />

I I<br />

Low portJ L High port<br />

4. Ring Transfer Recall Time is the time it takes to recall a station that originates an unanswered or busy (camped-on)<br />

transferred call.<br />

5. Ring Transfermustbe allowed (Program 10-1, LED 07ON) for transferrecall to function; otherwise Recall willbe immediate.<br />

6. Ring Transfer to stations in the Do Not Disturb Mode is not allowed; recall will be immediate if it is attempted-no matter what<br />

the Program 37 recall time is.<br />