INSTALLATION-CONFIGURATION<br />

SECTION 100-8<strong>16</strong>-203<br />

MARCH 1993<br />

<strong>DK</strong>8 WORKSHEET 2, KEY SERVICE UNIT AND PCBs<br />

1. From Worksheet 1 enter the number of required ports (circuits) and lines.<br />

Digital Ports: - (8 max)<br />

Standard Ports: (2 max)<br />

CO Lines: (4 max)<br />

NOTE: The maximum number of digital ports is 8, and standard ports is 2. The<br />

maximum number of CO lines is four.<br />

2. Cross off the printed circuit boards (PCBs)-in addition to the standard Base Key Service Unit lines and<br />

ports- needed to support the ports and lines entered in Step 1 of this worksheet.<br />

KSU Interfaces (built-in)<br />

2 CO lines, 4 digital ports<br />

KSU Optional Unit Station and Line PCBs<br />

QCDU (1 CO line and<br />

2 digital ports): two max.<br />

QSTU (2 standard ports): one max.<br />

3. Refer to Worksheet 3 to determine option and peripheral requirements.<br />