04.06.2013 Views

Strata DK 16 Manual

Strata DK 16 Manual

Strata DK 16 Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INSTALLATION-OK <strong>16</strong> KSU & PCB<br />

SECTION 100-8<strong>16</strong>-205<br />

MARCH 1993<br />

2)<br />

potentially hazardous- ring voltage. Do not<br />

remove this shield.<br />

Ensure that the PSTU subunit (SSTU) is se-<br />

curely attached to the PSTU (refer to Figure 5<br />

15).<br />

NOTE:<br />

WI, the ring generator level option, should be<br />

set in the H position (factory) for initial instal-<br />

la tion.<br />

3) Insert the PSTU into the appropriate slot (refer<br />

to Paragraph 5.22), and apply firm, even<br />

pressure to ensure proper mating of connec-<br />

tors.<br />

9.30 PSTU Wiring<br />

9.31 Refer to PSTU Wiring Diagram, Section IOO-<br />

8<strong>16</strong>-208, for wiring/interconnecting details.<br />

9.32 The PSTU is registered for use with OL13A<br />

type lines for off-premises stations.<br />

9.40 PSTU Programming Overview<br />

9.41 The following parameters may be specified,<br />

through programming, for the PSTU:<br />

Program 03<br />

l Specify code 31 for all slots that have PSTUs<br />

installed.<br />

Program 31<br />

l Used to configure all PSTU ports connected to<br />

voice mail (Section 100-8<strong>16</strong>-207 for more de-<br />

tails).<br />

Program 1 O-2<br />

l Used to set standard telephone ringing option.<br />

l Also used for BGM connection.<br />

Program 19<br />

l Used for BGM connection also.<br />

10 STANDARD/ELECTRONIC TELE-<br />

PHONE INTERFACE UNIT (PESU)<br />

10.00 General<br />

10.01 The Standard/Electronic Telephone Inter-<br />

face Unit (PESU) provides two standard telephone<br />

interface circuits (1 and 2) identical to PSTU circuits<br />

for connection between standard telephones, or<br />

5-22<br />

two-wire devices, and the system. It also provides<br />

four electronic telephone interface circuits (5 - 8)<br />

identical to PEKU circuits for connecting electronic<br />

telephones, BGM or an external amplifier. The<br />

PESU provides a ring generator for circuits 1 and 2<br />

(with a ring voltage of either 19OV P-P or 130V P-<br />

P), and it must be installed in the Expansion Unit.<br />

l The PESU does not support an HDSS console<br />

connection.<br />

l The PESU provides connectors to mount the<br />

EOCU for OCA to electronic telephones.<br />

NOTE:<br />

A KSU must be installed in the Base Unit for<br />

the system to recognize Dual-Tone Multi-<br />

Frequency (DTMF) tones sent from standard<br />

telephones or other two-wire devices that are<br />

connected to the PESU.<br />

10.02 The PESU controls and interface connectors<br />

are shown in Figure 5-<strong>16</strong> and described in Table<br />

5-D.<br />

10.10 PESU Hardware Options<br />

10.11 The PESU supports the following hardware<br />

options:<br />

l Internal option: Off-hook Call Announce<br />

(EOCU).<br />

NOTE:<br />

Refer to Section 1 OO-8<strong>16</strong>-206and Section 1 OO-<br />

8<strong>16</strong>-207 for installation of external options.<br />

10.12 Off-hook Call Announce (EOCU) Installa-<br />

tion. Install the Off-hook Call Announce in accor-<br />

dance with the following steps:<br />

1) Remove the PCB from its protective packaging.<br />

NOTE:<br />

PESU connectors PlO, P20, P40, P50, and<br />

P60 are positioned to allow installation of the<br />

EOCU only in the proper position (refer to<br />

Figure 5- <strong>16</strong>).<br />

2) Mate the EOCU connectors Jl 0,520, J40, J50,<br />

and J60 with the PESU connectors PlO, P20,<br />

P40, P50, and P60 (refer to Figure 5-<strong>16</strong>).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!