CO LINE<br />

NUMBERS<br />

81<br />

81<br />

00<br />

01<br />

/ \<br />

8<br />

ldp<br />

11111111oooooooo-<br />

(CO LINE)<br />

(LEDs ON)<br />

(LEDs OFF)<br />

81 02 00000000<br />

81 03 00000000<br />

81 04 00000000<br />

81 05 00000000<br />

81 06 00000000<br />

II<br />

COLlNE08’ tCOLINEO1<br />

STATION PORT<br />

NUMBERS<br />

PROGRAM NUMBER<br />

NOTES:<br />

1. In this example all lines are programmed to immediately ring the station at port 00 only.<br />

2.O=LEDof, l=LEDon.<br />

FIGURE 7-21<br />

PIOU/PIOUS SMDR PORT (PROGRAM 97) DATA DUMP EXAMPLE<br />

l Voice Mail Control from digital and electronic<br />

telephone<br />

l System Monitoring<br />

l Feature Integration<br />

7.12 A block diagram of voice mail connections is<br />

shown in Figure 7-22. See Section IOO-8<strong>16</strong>-204for<br />

QSTU and Section 100-8<strong>16</strong>-205 for PSTU, KSTU,<br />

and PESU installation instructions.<br />

7.13 STRATA <strong>DK</strong>8and <strong>DK</strong>I 6/VP Programming<br />

Considerations. Some features of STRATA <strong>DK</strong>8<br />

and <strong>DK</strong><strong>16</strong> system programming are intended for<br />

Toshiba VP, and are not necessarily available for<br />

customer-supplied voice mail messaging systems.<br />

These programming features are:<br />

l Answer (A)Tone. The STRATA <strong>DK</strong>8 and <strong>DK</strong><strong>16</strong><br />

stations will send an answer tone to Toshiba VP<br />

when the station answers a Toshiba VP call.<br />

l Disconnect (D) Tone. The STRATA <strong>DK</strong>8 and<br />

<strong>DK</strong><strong>16</strong> stations will send a disconnect tone to<br />

Toshiba VP when the station hangs up while<br />

connected to Toshiba VP. (D-Tone is also sent to<br />

7-29<br />

INSTALLATION-PERIPHERALS<br />

SECTION 100-8<strong>16</strong>-207<br />

MARCH 1993<br />

release the Toshiba VP auto attendant port<br />

when an outside CO line caller hangs-up and the<br />

Central Office provides a disconnect signal, per<br />

Program 15-O and 15-3.)<br />

NOTE:<br />

1. Not all Central Offices provide the discon-<br />

nect signal (calling party control) so this<br />

feature will not operate in all areas.<br />

2. Both answer and disconnect tones pro-<br />

vide more efficient Toshiba VP port use.<br />

Always enable these options. Both op-<br />

tions are enabled by accessing Program<br />

31 andsetting LED 15 to ON(LEDs <strong>16</strong>and<br />

17 must also be ON to allow A and D<br />

tones), and by accessing Program 15-O<br />

and 15-3andenablingCOlines withARVM<br />

and A ROH calls.<br />

3. The AR signal of some Central Offices is<br />

not reliable and may occur at times during<br />

a CO line voice connection causing the<br />

call to disconnect during a conversation. If<br />

thisoccurs, disable AROHandARVMcalls<br />

on all CO lines (Program 15-O and 15-3).