104<br />

piezo-electric crystal. When the accelerom-<br />

eter is subjected to acceleration, the mass<br />

acts on the crystal with a force proportional<br />

to the acceleration. The force exerted on the<br />

crystal will cause the crystal to send out a<br />

charge proportional to the acceleration. The<br />

signal can be fed into a computer for evalua-<br />

tion via a charge amplifier.<br />

When measuring vibration in a hand-<br />

held power tool with a complex motion, the<br />

location of the transducer obviously has a<br />

Charge<br />

amplifier<br />

Three operators<br />

Front end<br />

B&K Puls<br />

Fig. 3.14 Conducting laboratory measurements using EN/ISO 8662.<br />

significant influence on the result. Some<br />

literature, in particular that dealing with<br />

exposure measurements, suggests that the<br />

transducer should be located where the<br />

operator places his hands.<br />

If we take a grinding machine as an<br />

example, there are many points along the<br />

handle where the transducer can be placed.<br />

Each will give different readings. For some<br />

machines the lowest and highest reading<br />

may differ by a factor of five – sometimes<br />

Frequency spectra<br />

Computer with<br />

B&K Puls Software