[CCC] Communication error between the inserter and finisher<br />

Is the harness between the finisher control board and inserter control board normal?<br />

YES<br />

Replace the harness.<br />

Is 5V output to CN13-5 on the inserter control board?<br />

NO<br />

Replace the inserter control board.<br />

[CCD] Abnormal inserter EEPROM<br />

Replace the finisher control board.<br />

Is the conductor pattern around IC5 on the inserter control board short- or open-circuited?<br />

YES<br />

1. Replace the inserter control board.<br />

2. Perform the inserter tray volume adjustment.<br />

[CCE] Abnormal inserter fan<br />

Is the harness between the inserter control board and inserter fan normal?<br />

YES<br />

Replace the harness.<br />

Is the conductor pattern around Q11, Q16 and CN8 on the inserter control board short- or open-<br />

circuited?<br />

YES<br />

NO<br />

YES<br />

NO<br />

NO<br />

Replace the inserter fan.<br />

Replace the inserter control board.<br />