[CB2] Abnormal delivery motor<br />

Rotate the delivery motor by hand. Does it rotate smoothly?<br />

YES<br />

NO<br />

Fix the mechanism.<br />

Is the delivery motor clock sensor (PI10) working normally?<br />

YES<br />

NO<br />

Replace the sensor.<br />

Does the voltage between J11-4 and -5 on the finisher controller PC board become 24V when the<br />

delivery motor starts rotating?<br />

YES<br />

NO<br />

Replace the finisher controller PC board.<br />

Is the wiring between the delivery motor and finisher controller PC board correct?<br />

NO<br />

YES<br />

Replace the motor.<br />

Correct the wiring.<br />