[C4A] Cleaning web finished<br />

(1) Check if the cleaning web is remaining.<br />

(2) Check if the connector J332 on the LGC board is not disconnected.<br />

(3) Check if there is no abnormality at the web sensor.<br />

(4) Replace the LGC board.<br />

[CD5] Abnormality at the web motor signal path<br />

(1) Check if the connector of the web motor and connector pins are not disconnected.<br />

(2) Check if the drawer connector and connector pins are not disconnected.<br />

(3) Check if the harness between the drawer connector and the web motor is not open-circuited.<br />

(4) Check if the connector of the LGC board and connector pins are not disconnected.<br />

(5) Check if the harness between the connector of the LGC board and the drawer connector is not open-<br />

circuited.<br />

(6) Replace the LGC board.<br />

(7) Replace the fuser unit.<br />