SHARP TROUBLE & ERROR CODES AR-651, AR-810 - OlsonBros
SHARP TROUBLE & ERROR CODES AR-651, AR-810 - OlsonBros
SHARP TROUBLE & ERROR CODES AR-651, AR-810 - OlsonBros
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
[C1C] External LCF tray motor driving abnormally (Feeding is abled from the cassettes other<br />
than the external LCF.)<br />
Is the tray motor driving? (Perform the output check in the test mode: 03-271)<br />
YES<br />
1. Check if the connector J815 on the LCF tray motor is not disconnected.<br />
2. Check if the connectors J801~804 on the LCF board are not disconnected.<br />
3. Check if the connector of the tray-up sensor is not disconnected.<br />
4. Check if the actuator reaches the sensor.<br />
5. Check if the power (24V) is supplied to 1pin and 2pin of J803. If not, check if<br />
the door switch is turned ON and the harness of it is not open-circuited.<br />
6. Replace the LCF board.<br />
7. Replace the LGC board.<br />
Is the tray-up sensor working? (Perform the input check in the test mode: 03-[ENERGY SAVER]<br />
OFF/[1]/[C]<br />
YES<br />
NO<br />
NO<br />
1. Check if the connector of the tray-up sensor is not disconnected.<br />
2. Check if the connectors J801~804 on the LCF board are not disconnected.<br />
3. Check if the actuator reaches the sensor.<br />
4. Check if the coppector pins are not disconnected and the harness is not<br />
open-circuited.<br />
5. Replace the LCF board.<br />
6. Replace the LGC board.<br />
1. Check if the tray lifting mechanism has no abnormality.<br />
2. Replace the LCF board.<br />
3. Replace the LGC board.<br />
5 - 57 <strong>AR</strong>-<strong>651</strong>/<strong>810</strong> <strong>TROUBLE</strong> SHOOTING