5. 1. 15. Service call for others<br />

[C94] Abnormal main CPU<br />

Is the “Call for Service” displayed even after the main switch is turned OFF and back ON ?<br />

YES<br />

NO<br />

Leave it and see what happens.<br />

1. Check if the circuit pattern between the main CPU and MROM is short- or open-circuited.<br />

2. Replace the LGC board if this error occurs frequently.<br />

[F10] HDD Initialization error<br />

(1) Initialize the HDD. (mode (08) code "690" 2)<br />

(2) Check if the HDD is mounted.<br />

(3) Check if the specified HDD is mounted.<br />

(4) Check if the connector pins of the HDD are bent.<br />

(5) Check if the power supply connector is disconnected.<br />

(6) Check if the connector J107 on the SYS board is disconnected.<br />

(7) Replace the HDD.<br />

(8) Replace the SYS board.<br />

(9) Replace the harness.<br />

5 - 101 <strong>AR</strong>-<strong>651</strong>/<strong>810</strong> <strong>TROUBLE</strong> SHOOTING