05.08.2013 Views

SHARP TROUBLE & ERROR CODES AR-651, AR-810 - OlsonBros

SHARP TROUBLE & ERROR CODES AR-651, AR-810 - OlsonBros

SHARP TROUBLE & ERROR CODES AR-651, AR-810 - OlsonBros

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

[E57] Leading edge of paper not reaching the reverse sensor 1<br />

Is there any paper before the registration sensor when the exit cover is opened?<br />

NO<br />

Remove the paper.<br />

Is the reverse sensor 1 working? (Perform the input check in the test mode: 03-[ENERGY<br />

SAVER]OFF/[2]/[B])<br />

YES<br />

1. Check if the connector of the reverse sensor 1 is not disconnected.<br />

2. Check if the connector J335 on the LGC board is not disconnected.<br />

3. Check if the connector pins are not disconnected and the harness is not<br />

open-circuited.<br />

4. Check if the conductor pattern on the LGC board is not short- or open-<br />

circuited.<br />

5. Replace the reverse sensor 1.<br />

6. Replace the LGC board.<br />

Is the reverse motor driving? (Perform the output check in the test mode: 03-126)<br />

YES<br />

1. Check if the connector of the reverse transport unit is not disconnected.<br />

2. Check if the connector J335 on the LGC board is not disconnected.<br />

3. Check if the connector pins are not disconnected and the harness is not<br />

open-circuited.<br />

4. Check if the conductor pattern on the LGC board is not short- or open-<br />

circuited.<br />

5. Replace the LGC board<br />

Is the gate solenoid working? (Perform the output check in the test mode: 03-274)<br />

YES<br />

YES<br />

NO<br />

NO<br />

NO<br />

1. Check if the connector of the gate solenoid is not disconnected.<br />

2. Check if the connector J335 on the LGC board is not disconnected.<br />

3. Check if the connector pins are not disconnected and the harness is not<br />

open-circuited.<br />

4. Check if the conductor pattern on the LGC board is not short- or open-<br />

circuited.<br />

5. Replace the LGC board<br />

1. Check if there is no mechanical loading at the exit/reversal gate.<br />

2. Check the myler at the reverse section and clean it, or if it is deteriorated, replace it.<br />

5 - 29 <strong>AR</strong>-<strong>651</strong>/<strong>810</strong> <strong>TROUBLE</strong> SHOOTING

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!