5. 1. 9. Scanning system related service call<br />

[C26] Peak detection error<br />

Does the exposure lamp light? (Perform the output check in the test mode: 03-267)<br />

NO<br />

YES<br />

1. Check if the connectors on the CCD and SLG boards are disconnected.<br />

2. Check if the shading correction plate is dirty.<br />

3. Check if the conductor pattern on the CCD board is short- or open-circuited.<br />

4. Check if the conductor pattern on the SLG board is short- or open-circuited.<br />

5. Replace the lens unit.<br />

6. Replace the SLG board.<br />

1. Check if the connectors of the exposure lamp and inverter are disconnected.<br />

2. Check the SLG board if the connector pin J9 is disconnected and the harness is short- or open-<br />

circuited.<br />

3. Check if the conductor pattern on the SLG board is short- or open-circuited.<br />

4. Replace the SLG board.<br />

5. Replace the inverter.<br />

6. Replace the exposure lamp.<br />

<strong>AR</strong>-<strong>651</strong>/<strong>810</strong> <strong>TROUBLE</strong> SHOOTING 5 - 60